A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrophysiological characteristics and radiofrequency ablation of accessory pathways with slow conductive properties. | LitMetric

Background: Atrioventricular accessory pathways (AP) with unusually long ventriculo-atrial (VA) conduction times are present in a significant subset of patients with the Wolff-Parkinson-White (WPW) syndrome, not including patients with the permanent form of atrioventricular junctional reciprocating tachycardia.

Methods And Results: We compared the electrophysiological characteristics and outcomes after radiofrequency (RF) ablation in 34 patients with the WPW syndrome, a VA interval >80 ms, and paroxysmal tachycardia with an RP/PR ratio <1 (the slow group), vs 80 patients with WPW syndrome and a VA interval <80 ms (the fast group). AP were found in the posteroseptal region significantly more often in the slow than in the fast group. In addition, the decremental conductive properties of the AP were more common in the slow than in the fast group. Catheter ablation of AP was highly successful in both groups, although ablation required a greater number of RF applications and longer procedure times in the slow group, especially for AP with decremental conductive properties.

Conclusions: A posteroseptal AP location was more common in AP associated with long conduction times than in AP with typical conductive properties. Both types of AP were successfully ablated, although the slow group required longer procedures and more RF energy deliveries.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.68.1152DOI Listing

Publication Analysis

Top Keywords

electrophysiological characteristics
8
radiofrequency ablation
8
accessory pathways
8
wpw syndrome
8
characteristics radiofrequency
4
ablation accessory
4
pathways slow
4
slow conductive
4
conductive properties
4
properties background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!