A 6 Fr guiding catheter is commonly used in the percutaneous coronary intervention (PCI). However, one of the limitations of the 6 Fr guiding catheter is its weak backup support compared to a 7 or an 8 Fr guiding catheter. In this article, we present a new system for PCI called the five-in-six system. Between March 2003 and September 2003, this system was tried on eight chronic total occlusion cases. The advantage of the five-in-six system is that it increases backup support of a 6 Fr guiding catheter.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.20223 | DOI Listing |
J Biophotonics
January 2025
Department of Electrical Engineering, Columbia University, New York, New York, USA.
Epicardial catheter ablation is necessary to address ventricular tachycardia targets located far from the endocardium, but epicardial adipose tissue and coronary blood vessels can complicate ablation. We demonstrate that catheter-based near-infrared spectroscopy (NIRS) can identify these obstacles to guide ablation. Eighteen human ventricles were mapped ex vivo using NIRS catheters with optical source-detector separations (SDSs) of 0.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:
Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).
Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.
Ultrasound J
January 2025
Faculty of Medicine in Hradec Kralove, Charles University, Simkova 870, Hradec Kralove, 500 03, Czech Republic.
Background: The cannulation of the internal jugular vein (IJV) is a frequent procedure in critically ill patients. According to the guidelines, real-time ultrasound navigation is recommended. Traditional techniques pose several disadvantages, such as suboptimal needle visualization.
View Article and Find Full Text PDFInterv Neuroradiol
January 2025
Department of Neurology, Mayo Clinic Rochester, Rochester, MN, USA.
Background: The impact of certain comorbidities on mechanical thrombectomy (MT) outcomes remains largely unexplored. Diabetes mellitus (DM) and admission hyperglycemia have been associated with poor clinical outcomes for patients treated with MT. In this study, we sought to investigate the effects of DM and admission hyperglycemia on MT outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!