Preoperative evaluation of bone destruction using three-dimensional computed tomography in cholesteatoma.

J Laryngol Otol

Department of Otolaryngology, Wonkwang Medical School, Iksan, 570-711, South Korea.

Published: October 2004

This study investigated the usefulness of three-dimensional computed tomography (3DCT) in the evaluation of bony defects caused by cholesteatoma. Fifteen patients with chronic otitis media with cholesteatoma who showed bony destruction or suspicious destruction in two-dimensional CT were examined using 3DCT. The CT data were transferred to a workstation with a real-time image processor. We used three-dimensional reconstruction software enabling image processing. In all patients, 3DCT clearly delineated the destruction of bony structures by cholesteatoma. The 3DCT-generated images provided spatial relationships, which were not easily appreciated on two-dimensional CT. Intraoperative bony destruction findings correlated with 3DCT findings. From these results, 3DCT could be useful to evaluate the invasiveness of cholesteatoma to the cranial base. It could also be helpful in planning reconstruction during surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1258/0022215042450779DOI Listing

Publication Analysis

Top Keywords

three-dimensional computed
8
computed tomography
8
bony destruction
8
destruction
5
cholesteatoma
5
3dct
5
preoperative evaluation
4
evaluation bone
4
bone destruction
4
destruction three-dimensional
4

Similar Publications

Introduction The role of the condylar position in the correct functioning of the stomatognathic system has been the center of the study. Using cone-beam computed tomography (CBCT), this study looked at the three-dimensional (3D) position of the condylar bone in patients from Class I, Class II, Division 1, and Division 2. Materials and methods This cross-sectional, retrospective study was conducted using 102 CBCT records, with 34 records allocated to each category of malocclusion classification, such as dentoskeletal Class I, skeletal Class II, and dental Class II, Division 1 and 2.

View Article and Find Full Text PDF

Background/purpose: Computer-assisted implant surgery (CAIS) is increasingly performed to reduce deviations in implant position. Dynamic CAIS or navigation systems provide instant display of implant drilling instruments and patient positions directly on the computer monitor. Augmented reality (AR) technology allows operators to visualize real-time information projected onto the lenses of AR glasses.

View Article and Find Full Text PDF

Background: Three-dimensional rotational angiography (3DRA) is a promising advancement to guide cardiac catheterizations. It is used with restraint in critically ill infants with congenital heart disease (CHD) due to the lack of research conducted within this patient group.

Methods: Data of all infants with CHD and a body weight <5 kg who underwent cardiac catheterization with the use of 3DRA between November 2011 and April 2021 were retrospectively analyzed.

View Article and Find Full Text PDF

Insights into structural and binding studies of pollen allergen Bet v 1 using computational approaches.

In Silico Pharmacol

January 2025

Bioinformatics Infrastructure Facility, Sri Venkateswara College (University of Delhi), Benito Juarez Road, Dhaula Kuan, New Delhi, 110021 India.

Unlabelled: Bet v 1, the European White Birch tree pollen allergen is responsible for a number of allergic responses in humans such as rhinitis, asthma and oral allergy syndrome. The allergen belongs to pathogenesis-related (PR) class 10 protein superfamily and exists in several naturally occurring isoforms. Limited structural information on Bet v 1 isoallergens and variants prompted us to carry out their in silico structural characterization.

View Article and Find Full Text PDF

The combination of an ordinary s-type superconductor with three-dimensional topological insulators creates a promising platform for fault-tolerant topological quantum computing circuits based on Majorana braiding. The backbone of the braiding mechanism are three-terminal Josephson junctions. It is crucial to understand the transport in these devices for further use in quantum computing applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!