We report visualization of a prominent coronary sinus os valve (Thebesian valve), by electron beam computed tomographic angiography, which impeded an endocardial approach to left ventricular pacing. Resynchronization therapy was therefore performed with an epicardial approach to left ventricular lead placement. Electron beam computed tomographic angiography can provide detailed information for coronary sinus instrumentation, including anomalies potentially affecting the approach to resynchronization therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2004.00678.xDOI Listing

Publication Analysis

Top Keywords

electron beam
12
resynchronization therapy
12
thebesian valve
8
coronary sinus
8
beam computed
8
computed tomographic
8
tomographic angiography
8
approach left
8
left ventricular
8
valve imaging
4

Similar Publications

High-Q Emission from Colloidal Quantum Dots Embedded in Polymer Quasi-BIC Metasurfaces.

Nano Lett

January 2025

Department of Electrical and Computer Engineering, Northwestern University, Evanston, Illinois 60208, United States.

Metasurfaces supporting narrowband resonances are of significant interest in photonics for molecular sensing, quantum light source engineering, and nonlinear photonics. However, many device architectures rely on large refractive index dielectric materials and lengthy fabrication processes. In this work, we demonstrate quasi-bound states in the continuum (quasi-BICs) using a polymer metasurface exhibiting experimental quality factors of 305 at visible wavelengths.

View Article and Find Full Text PDF

An applied noise model for low-loss EELS maps.

Ultramicroscopy

January 2025

Nanopatterning-Nanoanalysis-Photonic Materials Group, Department of Physics, Paderborn University, Warburgerstr. 100, Paderborn, 33098, Germany. Electronic address:

Electron energy-loss spectroscopy (EELS) performed in a scanning transmission electron microscope (STEM) is susceptible to noise, just like every other measurement. EELS measurements are also affected by signal blurring, related to the energy distribution of the electron beam and the detector point spread function (PSF). Moreover, the signal blurring caused by the detector introduces correlation effects, which smooth the noise.

View Article and Find Full Text PDF

In this study, we explore the structural intricacies of cellulose, a polymer composed of glucose monomers arranged in a linear chain, primarily investigated through solid-state NMR techniques. Specifically, we employ low-field proton nuclear magnetic resonance (H-NMR) to delve into the diverse hydrogen atom types within the cellulose molecule. The low-field H-NMR technique allows us to discern these hydrogen atoms based on their distinct chemical shifts, providing valuable insights into the various functional groups present in cellulose.

View Article and Find Full Text PDF

InSb is a material of choice for infrared as well as spintronic devices but its integration on large lattice mismatched semi-insulating III-V substrates has so far altered its exceptional properties. Here, we investigate the direct growth of InSb on InP(111)B substrates with molecular beam epitaxial growth. Despite the lack of a thick metamorphic buffer layer for accommodation, we show that quasi-continuous thin films can be achieved using a very high Sb/In flux ratio.

View Article and Find Full Text PDF

Superficial lesions of the face are often treated with an electron beam and surface collimation utilizing a conformal lead shield with an opening around the region of treatment (ROT). To fabricate the lead shield, an imprint of the patient face is needed. Historically, this was achieved using a laborious and time-consuming process that involved a gypsum imprinted model (GIM) of the patient topography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!