Branch angle and flow into a symmetric bifurcation.

J Biomech Eng

Advanced Computing Center, The Institute of Physical and Chemical Research (RIKEN), 2-1, Hirosawa, Wako-shi, Saitama 351-0198, Japan.

Published: August 2004

Arterial branches are found to be a major site for formation of arterial plaque. In this study, we investigate the role of the bifurcation angle on the flow into a symmetric bifurcation. Specially, how the changes in the bifurcation angle influences the distribution of axial wall shear in the bifurcation model. The flow in a range of branch opening half-angle of pi/25< or =theta< or =pi/4 are numerically simulated. The flow in the above models is calculated for the inlet flow Reynolds numbers of 250, 500, 1000, and 2000. It is found that at higher values of the opening angle of the bifurcation, the possibility and severity of flow separation at the appropriate wall location increases.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.1785809DOI Listing

Publication Analysis

Top Keywords

angle flow
8
flow symmetric
8
symmetric bifurcation
8
bifurcation angle
8
flow
6
bifurcation
6
branch angle
4
bifurcation arterial
4
arterial branches
4
branches major
4

Similar Publications

Monitoring and optimization of the microenvironment in a gravity-driven microfluidic system placed on a slow-tilting table.

J Biosci Bioeng

January 2025

Department of Bioengineering, Nagaoka University of Technology, 1603-1 Kamitomioka-machi, Nagaoka, Niigata 940-2188, Japan; Department of Science of Technology Innovation, Nagaoka University of Technology, 1603-1, Kamitomioka-machi, Nagaoka, Niigata, 940-2188 Japan. Electronic address:

Gravity-driven microfluidic chips offer portability and flexibility in different settings because pumps and connecting tubes are unnecessary for driving fluid flow. In a previous study, human induced pluripotent stem cells were cultured using gravity-driven microfluidics, with the liquid flow rate regulated by a tilting table. However, instability in cell culture has been observed, occasionally leading to cell death owing to unknown causes.

View Article and Find Full Text PDF

Objective: To analyze the effect of the thoracoabdominal rebalancing (TAR) method on respiratory biomechanics, respiratory discomfort, pain sensation, and physiological parameters in moderate preterm newborns, compared to a control group.

Methods: This randomized clinical trial was conducted in a neonatal intensive care unit. The evaluation included: Neonatal Infant Pain Scale, physiological parameters, Silverman-Andersen score, and biomechanics (thoracic cirtometry and Charpy angle).

View Article and Find Full Text PDF

An emulsion of silicone oil droplets in aqueous buffer produces a distinctive series of peaks or resonances in the side scatter histogram in a flow cytometer. As many as 12 peaks are observed in the violet-side scatter channel at 405 nm, with half that number observed in the blue side scatter channel at 488 nm. Using the index of refraction of the oil and buffer, the wavelength of light, and the collection angle and gain of the instrument, we assign the peaks to specific diameters at which Mie resonances occur.

View Article and Find Full Text PDF

Background: Recurrent coarctation of the aorta (re-CoA) is a well-known although not fully understood complication after surgical repair, typically occurring in 10%-20% of cases within months after discharge.

Objectives: To (1) characterize geometry of the aortic arch and blood flow from pre-discharge magnetic resonance imaging (MRI) in neonates after CoA repair; and (2) compare these measures between patients that developed re-CoA within 12 months after repair and patients who did not.

Methods: Neonates needing CoA repair, without associated major congenital heart defects, were included.

View Article and Find Full Text PDF

The results of an investigation of an impact of the structure of recently synthesized bis(trifluoromethylsulfonyl)imide mono- and dicationic ionic liquids on their properties and behavior as lubricants for slippery liquid infused superhydrophobic coatings are presented for a wide temperature range. In this study, a new approach based on monitoring the surface tension of a liquid sessile droplet on top of a coating was exploited for the analysis of the evolution of the coating properties in prolonged contact with the liquid. It was found that the continuous contact with water flow results in slippery property degradation according to two different scenarios.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!