Purpose: To develop and evaluate a novel bleb grading scheme for clinical and photographic evaluation.

Method: A system for grading bleb photographs using widely applicable parameters was designed, and reference color photographs printed. A prospective masked agreement study was undertaken comparing slit lamp examination with mono and stereo photographs; 36 eyes of 28 patients with previous glaucoma surgery were graded according to defined parameters on a 1 to 10 scale clinically at the slit lamp by four ophthalmologists and two optometrists. Standardized stereo and mono photographs of the blebs were taken on the same day. The photographs were graded at least one week later in a masked fashion by the same observers, with grading of mono and stereo photographs also separated by one week. Analysis was performed to determine the variability and agreement between slit lamp results and photographic results, and to identify the presence of systematic bias.

Results: High levels of agreement were found between slit lamp and both stereo and mono photographs for vascularity indices, bleb wall thickness, and bleb elevation. Lower levels of agreement were found for the relative components of demarcated versus diffuse areas of the bleb, and for the total width of the bleb. The interquartile range for the median difference between slit lamp and photograph grading was -1.0 to 1.0 for all criteria except diffuse component (-2.0 to 2.0), and the median difference for all scores was 0.0. The median interobserver difference for all criteria was 0.0; the quartile range for all scores was between -0.5 and 1.0 except for diffuse component and width assessments whose quartiles fell in the -1.75 to 1.0 range. Examiners agreed with photographic grading within +/- 1 in more than 80% of gradings for vascularity and bleb height, within +/- 1 in more than 75% of gradings for bleb wall thickness, within +/- 2 in 61% of bleb width assessments, and +/- 2 in 59% of diffuse component.

Conclusion: This bleb grading system is reproducible clinically and photographically. High levels of agreement between scores for photographs versus slit lamp examination were found for most categories, with good interobserver agreement for both photograph and slit lamp grading. Further refinement of scoring and reference photographs is required for optimization, especially for grading of bleb morphology.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00061198-200412000-00005DOI Listing

Publication Analysis

Top Keywords

slit lamp
28
levels agreement
12
bleb
11
grading
9
photographs
9
system grading
8
glaucoma surgery
8
bleb grading
8
grading bleb
8
lamp examination
8

Similar Publications

This study investigates the association between self-reported birth weight (BW) and the frequency of cataract and pseudophakia in a large population-based cohort in Germany, as part of the Gutenberg Health Study (GHS). Slit lamp examination and Scheimpflug imaging of 8205 participants, aged 35 to 74, were assessed and signs of cataract or pseudophakia analyzed. The research aimed to explore the correlation between fetal growth restriction and/or prematurity indicated by BW and the frequency of cataract and pseudophakia.

View Article and Find Full Text PDF

Purpose: To report a case with bilateral corneal arcus and bilateral choroidal osteoma associated with H syndrome.

Methods: Descriptive case report.

Results: A 16-year-old girl with H syndrome was followed up in the pediatric nephrology clinic for chronic renal failure and was consulted to the ophthalmology clinic.

View Article and Find Full Text PDF

Background: Age is the principal risk factor for neurodegeneration in both the retina and brain. The retina and brain share many biological properties; thus, insights into retinal aging and degeneration may shed light onto similar processes in the brain. Genetic makeup strongly influences susceptibility to age-related retinal disease.

View Article and Find Full Text PDF

This study aimed to evaluate ocular surface temperature (OST) in post-COVID-19 patients with different degrees of fever via infrared thermal imaging. There were 16 participants (32 eyes) in the control group, 22 participants (44 eyes) in the moderate and low post-COVID-19 fever group (M & L fever group), and 18 participants (36 eyes) in the high post-COVID-19 fever group (H fever group). All participants underwent an ophthalmic slit lamp examination and ocular thermography.

View Article and Find Full Text PDF

Rationale: Congenital ectropion uveae (CEU) is a rare, nonprogressive anomaly characterized by the proliferation of the iris pigment epithelium on the anterior surface of the iris, often associated with glaucoma. Due to its rarity and complexity, standardized glaucoma surgical management is limited. To our knowledge, the application of glaucoma drainage devices in CEU is rarely documented.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!