A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A high-performance liquid chromatographic method for determination of praziquantel in plasma. | LitMetric

A high-performance liquid chromatographic method for determination of praziquantel in plasma.

J Pharm Biomed Anal

Faculty of Allied Health Sciences, Pharmacology and Toxicology Unit, Thammasat University (Rangsit Campus), Paholyothin Road, Pathumthani 12121, Thailand.

Published: November 2004

A simple, sensitive, selective and reproducible method based on a reversed-phase chromatography was developed for the determination of praziquantel in human plasma. Praziquantel was separated from the internal standard (diazepam) on a Luna C18 column (250 mm x 4.6mm, 5 microm particle size), with retention times of 4.8 and 6.2 min, respectively. Ultraviolet detection was set at 21 7 nm. The mobile phase consisted of acetonitrile and distilled water (70:30, v/v), running through the column at a flow rate of 1.0 ml/min. The chromatographic analysis was operated at 25 degrees C. Sample preparation (1 ml plasma) was done by a single step liquid-liquid extraction with the mixture of methyl-tert-butylether and dichloromethane at the ratio of 2:1 (v/v). Calibration curves in plasma at the concentrations 0, 50, 100, 200, 400, 800 and 1600 ng/ml were all linear with correlation coefficients better than 0.999. The precision of the method based on within-day repeatability and reproducibility (day-to-day variation) was below 15% (relative standard deviation: R.S.D.). Good accuracy was observed for both the intra-day or inter-day assays, as indicated by the minimal deviation of mean values found with measured samples from that of the theoretical values (below +/-15%). Limit of quantification (LOQ) was accepted as 5 ng using 1 ml samples. The mean recovery for praziquantel and the internal standard were greater than 90% for both praziquantel and internal standard. The method was free from interference from the commonly used antibiotic and antiparasitic drugs. The method appears to be robust and has been applied to a pharmacokinetic study of praziquantel in three healthy Thai volunteers following a single oral dose of 40 mg/kg body weight praziquantel.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2004.07.043DOI Listing

Publication Analysis

Top Keywords

internal standard
12
determination praziquantel
8
method based
8
praziquantel internal
8
praziquantel
7
method
5
high-performance liquid
4
liquid chromatographic
4
chromatographic method
4
method determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!