Diagnosis of macular pseudoholes and lamellar macular holes by optical coherence tomography.

Am J Ophthalmol

Department of Ophthalmology, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Université, Paris, France.

Published: November 2004

AI Article Synopsis

Article Abstract

Purpose: To assess the usefulness of optical coherence tomography (OCT) for better differential diagnosis of macular pseudoholes (MPH) and lamellar macular holes (LMH).

Design: Observational case series.

Methods: setting: Institutional practice. patients: We reviewed the files of 71 eyes of 70 consecutive patients who were diagnosed as having a pseudohole or lamellar hole on OCT examination. All patients referred for suspected pseudohole or lamellar hole on biomicroscopy were evaluated by OCT. main outcome measures: Each eye underwent six radial 3-mm OCT scans centered on the macula, one 6-mm vertical and one 6-mm horizontal scan. Retinal thickness was measured at the foveal center and 750 microm from the center, vertically, and horizontally. The diameter of the macular contour was also measured on vertical and horizontal scans.

Results: In 40 cases, OCT showed a macular profile characteristic of MPH: a steepened foveal pit combined with thickened foveal edges and a small foveal pit diameter. Central foveal thickness was normal or slightly increased (167 +/- 42 microm). Mean perifoveal thickness was greater than normal (363 +/- 65 microm). In 29 other cases corresponding to LMH, OCT showed a profile characterized by a thin irregular foveal floor, split foveal edges, and near-normal perifoveal retinal thickness. Central foveolar thickness was thinner than normal (72 +/- 19 microm). Mean perifoveal thickness was near normal (283 +/- 36). Optical coherence tomography did not allow the classification of the remaining two cases.

Conclusions: Optical coherence tomography is very useful in distinguishing MPH attributable to epiretinal membrane contraction from LMH because of partial opening of a macular cyst.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2004.06.088DOI Listing

Publication Analysis

Top Keywords

optical coherence
16
coherence tomography
16
+/- microm
12
diagnosis macular
8
macular pseudoholes
8
lamellar macular
8
macular holes
8
pseudohole lamellar
8
lamellar hole
8
retinal thickness
8

Similar Publications

Convergent-beam attosecond x-ray crystallography.

Struct Dyn

January 2025

Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany.

Sub-ångström spatial resolution of electron density coupled with sub-femtosecond to few-femtosecond temporal resolution is required to directly observe the dynamics of the electronic structure of a molecule after photoinitiation or some other ultrafast perturbation, such as by soft X-rays. Meeting this challenge, pushing the field of quantum crystallography to attosecond timescales, would bring insights into how the electronic and nuclear degrees of freedom couple, enable the study of quantum coherences involved in molecular dynamics, and ultimately enable these dynamics to be controlled. Here, we propose to reach this realm by employing convergent-beam x-ray crystallography with high-power attosecond pulses from a hard-x-ray free-electron laser.

View Article and Find Full Text PDF

Background: An idiopathic macular hole (IMH) is a foveal opening in the neurosensory retina caused by perifoveal vitreomacular traction and detachment. IMH prevalence varies considerably across populations, highlighting a need for further investigation, especially in underrepresented groups such as Hispanics.

Methods: This retrospective, descriptive, cross-sectional study analyzed IMH prevalence in a Hispanic population over four years.

View Article and Find Full Text PDF

The choroid, a critical vascular layer beneath the retina, is essential for maintaining retinal function and monitoring chorioretinal disorders. Existing imaging methods, such as indocyanine green angiography (ICGA) and optical coherence tomography (OCT), face significant limitations, including contrast agent requirements, restricted field of view (FOV), and high costs, limiting accessibility. To address these challenges, we developed a nonmydriatic, contrast agent-free fundus camera utilizing transcranial near-infrared (NIR) illumination.

View Article and Find Full Text PDF

Conventional scanned optical coherence tomography (OCT) suffers from the frame rate/resolution tradeoff, whereby increasing image resolution leads to decreases in the maximum achievable frame rate. To overcome this limitation, we propose two variants of machine learning (ML)-based adaptive scanning approaches: one using a ConvLSTM-based sequential prediction model and another leveraging a temporal attention unit (TAU)-based parallel prediction model for scene dynamics prediction. These models are integrated with a kinodynamic path planner based on the clustered traveling salesperson problem to create two versions of ML-based adaptive scanning pipelines.

View Article and Find Full Text PDF

Monte Carlo-based realistic simulation of optical coherence tomography angiography.

Biomed Opt Express

January 2025

Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.

Optical coherence tomography angiography (OCTA) offers unparalleled capabilities for non-invasive detection of vessels. However, the lack of accurate models for light-tissue interaction in OCTA jeopardizes the development of the techniques to further extract quantitative information from the measurements. In this manuscript, we propose a Monte Carlo (MC)-based simulation method to precisely describe the signal formation of OCTA based on the fundamental theory of light-tissue interactions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!