Acad Radiol
Department of Radiology, Weill Medical College of Cornell University, New York Presbyterian Hospital, 520 East 68th Street, Starr Pavilion, Starr-630, New York, NY 10021, USA.
Published: October 2004
Rationale And Objectives: Deconvolution-based software can be used to calculate quantitative maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) from first-pass computed tomography perfusion (CTP) datasets. The application of this software requires the user to select multiple input variables. The purpose of this study was to investigate the degree to which both major and minor variations of these user-defined inputs would affect the final quantitative values of CBF, CBV, and MTT.
Materials And Methods: A neuroradiologist constructed CBF, CBV, and MTT maps using standard methodology with commercially available software (GE Functool Version 1.9s) from CTP datasets of three acute stroke patients. Each map was reconstructed multiple times by systematically and independently varying the following parameters: postenhancement and preenhancement cutoff values, arterial and venous region-of-interest (ROI) placement, and arterial and venous ROI size. The resulting quantitative CTP values were compared using identical ROIs placed at the infarct core.
Results: Major variations of either arterial ROI placement or arterial and venous ROI size had no significant effect on the mean CBF, CBV, and MTT values at the infarct core (p > .05). Even minor variations, however, in the choice of venous ROI placement or in pre- and postenhancement cutoff values significantly altered the quantitative values for each of the CTP maps, by as much as threefold.
Conclusion: Even minor variations of user-defined inputs can significantly influence the quantitative, deconvolution-based CTP map values of acute stroke patients. Although quantitation was robust to the choice of arterial ROI placement and arterial or venous ROI size, it was strongly dependent on the choice of venous ROI location and pre- and postenhancement cut-off values. Awareness of these results by clinicians may be important in the creation of quantitatively accurate CTP maps.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acra.2004.07.002 | DOI Listing |
J Xray Sci Technol
January 2025
School of Medical Technology, Qiqihar Medical University, Qiqihar, China.
Background: Inflammation of coronary arterial plaque is considered a key factor in the development of coronary heart disease. Early the plaque detection and timely treatment of the atherosclerosis could effectively reduce the risk of cardiovascular events. However, there is no study combining radiomics with deep learning techniques to predict non-calcified plaques (NCP) in coronary artery at present.
View Article and Find Full Text PDFBMC Med Imaging
February 2025
Department of Radiology, The Second Hospital of Jilin University, Changchun, China.
Background: To investigate how effectively clinical features and CT-based radiomic features predict the pathological grade of hepatocellular carcinoma (HCC).
Methods: We retrospectively analyzed 108 patients diagnosed with hepatocellular carcinoma who underwent pathological examination between May 2020 and May 2024 at the Second Hospital of Jilin University. All patients underwent laboratory tests and contrast-enhanced computed tomography (CECT) scanning of the liver within one month prior to pathological examination.
Neurosurg Rev
February 2025
Neurosurgery Department, Priorov National Medical Research Center of Traumatology and Orthopedics, Priorova str, 10, Moscow, Russia.
Background: Although measuring vertebral bone density with the use of the computed tomography-based Hounsfield units (HU) is becoming increasingly popular, a much-desired standardized and robust method for measuring HU values accurately, quickly and conveniently was yet to exist.
Methods: Lumbar CT images of patients with degenerative lumbar diseases were analyzed. The HU values of the vertebral bodies were measured in three planes: mid-axial (including or not including the posterior venous plexus (PVP)), mid-sagittal and mid-frontal; the HU values of the vertebral pedicles were measured in two planes: axial and sagittal.
AJNR Am J Neuroradiol
February 2025
From the Department of Radiology (A.A.M, Z.Z, P.J.F, J.T., W.B, J.K.C-G, M.L.K, N.M.W, G.T, F.E.D., L.Y.), Mayo Clinic, Rochester, MN, USA and the Department of Radiology (T.J.A, P.G.K), Durham, NC, USA.
Background And Purpose: Photon counting detector CT myelography is a recently described technique used for detecting spinal CSF leaks, including CSF-venous fistulas. Various image reconstruction techniques, including smoother versus sharper kernels and virtual monoenergetic images, are available with photon counting CT. Moreover, denoising algorithms have shown promise in improving sharp kernel images.
View Article and Find Full Text PDFZhonghua Wei Zhong Bing Ji Jiu Yi Xue
December 2024
Department of Public Utilities Development, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, Henan, China.
Objective: To explore the effects of veno-venous extra corporeal carbon dioxide removal (V-V ECCOR) on local mechanical power and gas distribution in the lungs of patients with mild to moderate acute respiratory distress syndrome (ARDS) receiving non-invasive ventilation.
Methods: Retrospective research methods were conducted. Sixty patients with mild to moderate ARDS complicated with renal insufficiency who were transferred to the respiratory intensive care unit (RICU) through the 96195 platform critical care transport green channel from January 2018 to January 2020 at the collaborative hospitals of Henan Provincial People's Hospital were enrolled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!