This research is directed towards developing a more sensitive and rapid electrochemical sensor for enzyme labeled immunoassays by coupling redox cycling at interdigitated electrode arrays (IDA) with the enzyme label beta-galactosidase. Coplanar and comb IDA electrodes with a 2.4 microm gap were fabricated and their redox cycling currents were measured. ANSYS was used to model steady state currents for electrodes with different geometries. Comb IDA electrodes enhanced the signal about three times more than the coplanar IDAs, which agreed with the results of the simulation. Magnetic microbead-based enzyme assay, as a typical example of biochemical detection, was done using the comb and coplanar IDAs. The enzymes could be placed close to the sensing electrodes (approximately 10 microm for the comb IDAs) and detection took less than 1 min with a limit of detection of 70 amol of beta-galactosidase. We conclude that faster and more sensitive assays can be achieved with the comb IDA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2004.04.004 | DOI Listing |
Comb Chem High Throughput Screen
June 2024
Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Unlabelled: Since the authors are not responding to the editor’s requests to fulfill the editorial requirement, therefore, the article has been withdrawn from the journal Combinatorial Chemistry & High Throughput Screening. Bentham Science apologizes to the readers of the journal for any inconvenience this may have caused. The Bentham Editorial Policy on Article Withdrawal can be found at https://benthamscience.
View Article and Find Full Text PDFRev Sci Instrum
November 2022
Plasma Research Center, University of Tsukuba, Tsukuba 305-8577, Japan.
Doppler-backscattering (DBS) has been used in several fusion plasma devices because it can measure the perpendicular velocity of electron density perturbation v, the radial electric field E, and the perpendicular wavenumber spectrum S(k) with high wavenumber and spatial resolution. In particular, recently constructed frequency comb DBS systems enable observation of turbulent phenomena at multiple observation points in the radial direction. A dual-comb microwave DBS system has been developed for the large helical device plasma measurement.
View Article and Find Full Text PDFAnal Sci
August 2019
Graduate School of Material Science, University of Hyogo.
We applied a fabrication method for the formation of island organization of cells based on a three-dimensional (3D) device for negative dielectrophoresis (n-DEP) to produce cell aggregates with uniform numbers of cells rapidly and simply. The intersections formed by rotating the interdigitated array (IDA) with two combs of band electrodes on the upper substrate by 90° relative to the IDA with two combs on the lower substrate were prepared in the device. The AC voltage was applied to a comb on the upper substrate and a comb on the lower substrate, while AC voltage with opposite phase was applied to another comb on the upper substrate and another comb on the lower substrate.
View Article and Find Full Text PDFRev Sci Instrum
October 2018
National Institutes of Natural Sciences, National Institute for Fusion Science, Toki 509-5292, Japan.
We succeeded in increasing the radial observation points of the microwave frequency comb Doppler reflectometer system from 8 to 20 (or especially up to 45) using the high sampling rate of 40 GS/s digital signal processing. For a new acquisition system, the estimation scheme of the Doppler shifted frequency is constructed and compared with the conventional technique. Also, the fine radial profile of perpendicular velocity is obtained, and it is found that the perpendicular velocity profile is consistent with the × drift velocity one.
View Article and Find Full Text PDFRev Sci Instrum
July 2017
Plasma Research Lab, Australian National University, Canberra, Australia.
A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for.