Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: This study aimed to evaluate the technical feasibility and hemodynamic benefit of cardiac resynchronization therapy (CRT) in patients with systemic right ventricle (RV).
Background: Patients with a systemic RV are at high risk of developing heart failure. Cardiac resynchronization therapy may improve RV function in those with electromechanical dyssynchrony.
Methods: Eight patients (age 6.9 to 29.2 years) with a systemic RV and right bundle-branch block (n = 2) or pacing from the left ventricle (LV) (n = 6) with a QRS interval of 161 +/- 21 ms underwent CRT (associated with cardiac surgery aimed at decrease in tricuspid regurgitation in 3 of 8 patients) and were followed-up for a median of 17.4 months.
Results: Change from baseline rhythm to CRT was accompanied by a decrease in QRS interval (-28.0%, p = 0.002) and interventricular mechanical delay (-16.7%, p = 0.047) and immediate improvement in the RV filling time (+10.9%, p = 0.002), Tei index (-7.7%, p = 0.008), estimated RV maximum +dP/dt(+45.9%, p = 0.007), aortic velocity-time integral (+7.0%, p = 0.028), and RV ejection fraction by radionuclide ventriculography (+9.6%, p = 0.04). The RV fractional area of change increased from a median of 18.1% before resynchronization to 29.5% at last follow-up (p = 0.008) without a significant change in the end-diastolic area (+4.0%, p = NS).
Conclusions: The CRT yielded improvement in systemic RV function in patients with spontaneous or LV pacing-induced electromechanical dyssynchrony and seems to be a promising adjunct to the treatment and prevention of systemic RV failure.