Unlabelled: The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data.
Methods: Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by the planar method (planar GBP), were enrolled in this study. Planar GBP was performed with a single-headed gamma camera. From the left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG-gating during the equilibrium state. SPET GBP was conducted utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees by 60 sec per view, in 16 frames/cardiac cycle. In each frame, left ventricular volume was determined by automatic edge detection employing a quantitative gated SPET program. Additionally, the time-volume curve was fitted by the 4th harmonics of Fourier transform. Ejection fraction (EF, %), peak ejection rate (PER, /sec), peak filling rate (PFR, /sec) and mean filling rate during the initial one-third of diastolic time (1/3 FRm) were calculated from the fitted curve. These parameters were also calculated with planar GBP data.
Result: Left ventricular ejection and filling parameters were calculated by SPET GBP with the automatic edge detection program for all patient data. Correlation coefficients of EF, PER, PFR and 1/3 FRm between SPET and planar GBP were 0.91 (p < 0.001), 0.82 (p < 0.001), 0.78 (p < 0.001) and 0.74 (p < 0.001), respectively.
Conclusion: Ejection and filling rates can be calculated using SPET GBP with the edge-detection software. These parameters displayed significant correlations with those values obtained via planar GBP. Additional studies are warranted to determine the reliability of parameters with SPET GBP.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF02984568 | DOI Listing |
Ann Nucl Med
September 2004
Department of Biotracer Medicine, Kanazawa University Graduate School of Medical Sciences, Japan.
Unlabelled: The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data.
Methods: Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by the planar method (planar GBP), were enrolled in this study. Planar GBP was performed with a single-headed gamma camera.
Nucl Med Commun
May 2003
Department of 1Biotracer Medicine, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan.
An analysis program for ECG gated, blood pool, single photon emission tomography (SPET GBP) is available. This program permits the automatic evaluation of left and right ventricular function, but its reliability has not been thoroughly assessed. The objective of this investigation was to examine the reliability of the parameters derived from SPET GBP.
View Article and Find Full Text PDFEur J Nucl Med
October 2001
Department of Nuclear Medicine, Kanazawa University School of Medicine, Ishikawa, Japan.
The aim of this study was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling by the edge detection method with ECG-gated single-photon emission tomography (G-SPET) data. Fifty-two patients who had undergone both G-SPET and gated equilibrium blood pool scintigraphy (GBP) within an interval of 2 weeks were enrolled. For G-SPET, 740 MBq of technetium-99m methoxyisobutylisonitrile (MIBI) was injected at rest, and myocardial SPET was performed 60 min later using 360 degrees acquisition and 12 frames per cardiac cycle.
View Article and Find Full Text PDFEur J Nucl Med
May 2001
Department of Nuclear Medicine, Royal Brisbane Hospital, Herston, Australia.
Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured.
View Article and Find Full Text PDFG Ital Cardiol
November 1994
U.O. di Cardiologia, Ospedale di Prato, Università di Firenze.
Background: Pre and post treatment perfusion scintigraphy with Tc-99m-sestamibi is an accurate method to evaluate the effectiveness of thrombolytic therapy in patients with acute myocardial infarction. In the present study this method was used to verify whether thrombolytic therapy performed late (6 to 24 hours) after symptoms onset was still able to produce significant salvage of jeopardized myocardial tissue.
Methods: Fifteen patients (mean age 60.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!