Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.

Int J Oral Maxillofac Implants

Department of Restorative Dentistry, Faculty of Dentistry, National University of Singapore, Republic of Singapore.

Published: December 2004

Purpose: Critical bending moment (CBM), the moment at which the external nonaxial load applied overcomes screw joint preload and causes loss of contact between the mating surfaces of the implant screw joint components, was measured with 2 types of implants and 2 types of abutments.

Materials And Methods: Using 4 test groups of 5 implant-abutment pairs, CBM at the implant-abutment screw joint was measured at 25%, 50%, 75%, and 100% of the manufacturer's recommended torque levels. Regular Platform (RP) Nobel Biocare implants (3.75 mm diameter), Wide Platform (WP) Nobel Biocare implants (5.0 mm diameter), CeraOne abutments, and Multiunit abutments were used. Microstrain was measured as loads were applied to the abutment at various distances from the implant-abutment interface. Strain instrumentation logged the strain data dynamically to determine the point of gap opening. All torque applications and strain measurements were repeated 5 times.

Results: For the CeraOne-RP group, the mean CBMs were 17.09 Ncm, 35.35 Ncm, 45.63 Ncm, and 62.64 Ncm at 25%, 50%, 75%, and 100% of the recommended torque level, respectively. For the CeraOne-WP group, mean CBMs were 28.29 Ncm, 62.97 Ncm, 92.20 Ncm, and 127.41 Ncm; for the Multiunit-RP group, 16.08 Ncm, 21.55 Ncm, 34.12 Ncm, and 39.46 Ncm; and for the Multiunit-WP group, 15.90 Ncm, 32.86 Ncm, 43.29 Ncm, and 61.55 Ncm at the 4 different torque levels. Two-way analysis of variance (ANOVA) (P < .001) revealed significant effects for the test groups (F = 2738.2) and torque levels (F = 2969.0).

Discussion: The methodology developed in this study allows confirmation of the gap opening of the screw joint for the test groups and determination of CBM at different torque levels.

Conclusion: CBM was found to differ among abutment systems, implant diameters, and torque levels. The torque levels recommended by the manufacturer should followed to ensure screw joint integrity.

Download full-text PDF

Source

Publication Analysis

Top Keywords

screw joint
24
torque levels
24
ncm
16
test groups
12
torque
9
critical bending
8
bending moment
8
implant-abutment screw
8
25% 50%
8
50% 75%
8

Similar Publications

Background: This study aimed to investigate the safety and reliability of using bioabsorbable screws for the fixation of chevron osteotomy in the treatment of hallux valgus (HV) deformity.

Methods: Clinical cases of chevron osteotomy in the treatment of HV deformities in our hospital between December 2018 and August 2022 were retrospectively summarised to compare preoperative imaging indices with those at the final follow-up session, including the hallux valgus angle (HVA), intermetatarsal angle (IMA) and tibial sesamoid position (TSP). The American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal scale, short-form health survey questionnaire (SF-36) and European Foot and Ankle Society (EFAS) scale were used to assess therapeutic efficacy.

View Article and Find Full Text PDF

Background: Iatrogenic cervical kyphosis (ICK) often requires complex anterior and posterior correction, which is associated with multiple complications. Consequently, there is a need to investigate alternative treatment approaches that streamline the operative process and markedly diminish postoperative complications. This study, therefore, aimed to evaluate the feasibility and efficacy of a single-stage anterior controllable antedisplacement fusion (ACAF) in revision surgeries for ICK.

View Article and Find Full Text PDF

Background: Pediatric femoral neck fractures (PFNF) are rare but associated with a high rate of serious complications such as avascular femoral head necrosis (AVN). Major risk factors and prognostic tools for an AVN are still unclear. As AVN is a devastating complication, this study aims to evaluate the predictors for AVN following a PFNF.

View Article and Find Full Text PDF

Rationale: Alkaptonuria (AKU) is a rare, inherited metabolic disease caused by deficient activity of homogentisic acid oxidase, leading to the accumulation of homogentisic acid and its oxidized product, benzoquinone acetic acid. These compounds cause black discoloration of cartilage, degeneration, inflammation, and calcification of intervertebral disks and large joints, resulting in pain and impaired quality of life. Despite its debilitating effects, there are no curative treatments for AKU, and management remains supportive.

View Article and Find Full Text PDF

Background: In atlantoaxial instabilities, posterior C1/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.

Purpose: The aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!