Objective: The purpose of this study was to evaluate the diagnostic accuracy of hysterosalpingography (HSG) in comparison with hysteroscopy in the detection of intrauterine abnormality in infertile patients.

Materials And Methods: Seventy-eight patients being investigated for infertility and undergoing HSG and hysteroscopy were studied retrospectively. Radiologic findings on HSG, including single or multiple filling defects and uterine wall irregularities, were evaluated and compared with hysteroscopic findings, which were considered the reference standard.

Results: HSG showed a sensitivity of 81.2% compared with that of hysteroscopy and a specificity of 80.4%, with a positive predictive value of 63.4% and a negative predictive value of 83.7%. HSG also had a false-negative rate of 90% and a false-positive rate of 21.8%. Overall agreement between the two procedures was 73%.

Conclusion: HSG is still a useful screening test for the evaluation of the uterine cavity in the study of primary or secondary infertility. In addition, HSG provides information concerning the assessment of tubal morphology and patency. We believe that these two procedures are complementary in the evaluation of the uterine cavity.

Download full-text PDF

Source
http://dx.doi.org/10.2214/ajr.183.5.1831405DOI Listing

Publication Analysis

Top Keywords

detection intrauterine
8
comparison hysteroscopy
8
evaluation uterine
8
uterine cavity
8
hsg
7
diagnostic hysterosalpingography
4
hysterosalpingography detection
4
intrauterine abnormalities
4
abnormalities comparison
4
hysteroscopy
4

Similar Publications

Purpose: The purpose of this manuscript is to report a rare case of an orbital cyst detected intrauterine with sonography.

Observation: A 23-year-old female presented for routine prenatal monitoring when an orbital cyst was detected with a transabdominal ultrasound. Uncomplicated cesarean section was performed at 38 weeks gestation with proptosis of the left globe being noted on ophthalmic examination of the newborn.

View Article and Find Full Text PDF

Anti-Adhesive Podocalyxin Expression Is Disrupted in Recurrent Implantation Failure.

Diagnostics (Basel)

January 2025

Department of Obstetrics and Gynecology, IVF-Unit, Acibadem Kayseri Hospital, 38140 Kayseri, Türkiye.

The downregulation of anti-adhesive regulatory proteins and upregulation of adhesive genes are critical for the receptive endometrium. This study was designed to determine whether switching between the anti-adhesive podocalyxin (PDX) and adhesive HOXA10 receptivity modulator occurs in the endometrium of women with recurrent implantation failure (RIF). Twenty-four patients with RIF who could not conceive for three or more cycles despite good-quality embryo transfer constituted the study group.

View Article and Find Full Text PDF

The Emerging Role of Sonoelastography in Pregnancy: Applications in Assessing Maternal and Fetal Health.

Diagnostics (Basel)

December 2024

Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj 16278, Saudi Arabia.

Sonoelastography, a novel ultrasound-based technique, is emerging as a valuable tool in prenatal diagnostics by quantifying tissue elasticity and stiffness in vivo. This narrative review explores the application of sonoelastography in assessing maternal and fetal health, with a focus on cervical, placental, pelvic floor, and fetal tissue evaluations. In the cervix, sonoelastography aids in predicting preterm birth and assessing labor induction success.

View Article and Find Full Text PDF

Intrauterine growth restriction (IUGR) is the second most common obstetric complication after preterm labor. Appropriate trophoblast differentiation and placental structure, growth and function are key for the maintenance of pregnancy and normal fetal growth, development and survival. Extravillous trophoblast cell proliferation, migration and invasion are regulated by molecules produced by the fetomaternal interface, including autocrine factors produced by the trophoblast, such as insulin‑like growth factor (IGF)‑1.

View Article and Find Full Text PDF

Background: Maternal hypertensive disorders of pregnancy (HDP) was associated with increased risk of congenital hypothyroidism in preterm infants, but its underlying mechanisms remain unclear.

Objective: To investigate the possible mechanisms by which intrauterine exposure to HDP affects thyroid hormone synthesis in preterm infant rats.

Methods: preterm infant rats were obtained by Caesarean section delivery from the L-NAME group and Control groups which was induced by L-NAME and saline, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!