Lenticular levels of amino acids and free UV filters differ significantly between normals and cataract patients.

Invest Ophthalmol Vis Sci

Australian Cataract Research Foundation, University of Wollongong, Wollongong, New South Wales, Australia.

Published: November 2004

Purpose: To determine the levels of free UV filters and selected amino acids in cataract lenses compared with normal lenses.

Methods: Indian cataract lenses (n=39) and normal lenses (n=6) were examined by HPLC to quantify levels of UV filter compounds, the UV filter precursor amino acid tryptophan (Trp), as well as tyrosine (Tyr) and uric acid.

Results: The levels of the two major primate UV filters, 3-hydroxykynurenine glucoside (3OHKG) and 4-(2-amino-3-hydroxyphenyl)-4-oxobutanoic acid glucoside (AHBG), in cataract lenses were markedly decreased compared with levels in normal lenses. By contrast, the levels of Trp were greatly increased. Mean Trp concentrations were an order of magnitude higher than in normal lenses, with 86% of dark-colored cataract lens nuclei having Trp concentrations greater than the mean level in the normal lenses. The concentrations of Tyr were also higher in cataract lenses. The levels of Kyn, however, were unchanged, and the uric acid levels were substantially lower.

Conclusions: The levels of the free UV filter compounds 3OHKG and AHBG, and also of Trp, Tyr, and uric acid were different in cataract lenses compared to normal lenses. These data suggest that the metabolism of a large proportion of patients with cataract may be substantially different than in persons with normal lenses. Although the mechanism of such metabolic defects are unknown, the authors speculate that an amino acid transporter system may be upregulated in patients with cataract. Because kynurenine levels in cataract were not significantly different from those of normal lenses, there may be a defect in the lenticular UV filter pathway at one, or both, of the steps that convert kynurenine to 3OHKG.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.04-0178DOI Listing

Publication Analysis

Top Keywords

normal lenses
28
cataract lenses
20
lenses
12
cataract
10
levels
9
amino acids
8
free filters
8
levels free
8
lenses compared
8
normal
8

Similar Publications

Tungsten oxide (WO) electrochromic devices are obtaining increasing interest due to their color change and thermal regulation. However, most previous work focuses on the absorption or transmission spectra of materials, rather than the optical parameters evolution in full spectrum in the electrochromic processes. Herein, we developed a systematic protocol of ex situ methods to clarify the evolutions of subtle structure changes, Raman vibration modes, and optical parameters of WO thin films in electrochromic processes as stimulated by dosage-dependent Li insertion.

View Article and Find Full Text PDF

Use of refractive aids among adults in a general population.

Sci Rep

January 2025

Department of Clinical Medicine, Aarhus University, Aarhus N, DK-8200, Denmark.

Spectacles and contact lenses are important for conducting a normal life in a large part of the general population. The purpose of this study was to estimate the use of these refractive aids in a normal adult population, and to identify characteristics of persons who should be targeted in order to improve uncorrected refraction. In the FORSYN study, 10,350 citizens representative for the adult Danish population were invited for a non-cycloplegic eye examination.

View Article and Find Full Text PDF

[Cataracts extraction combined with multifocal intraocular lens optic implantation in Berger space in school-age children with cataracts].

Zhonghua Yan Ke Za Zhi

January 2025

Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, School of Ophthalmology, Shandong First Medical University, Qingdao266071, China.

To evaluate the safety and efficacy of cataract extraction combined with multifocal intraocular lens (IOL) optic implantation in Berger space in school-age children with cataracts. It was a prospective study. The clinical data of school-age children with cataract who underwent cataract extraction combined with multifocal IOL implantation at Qingdao Eye Hospital of Shandong First Medical University from January 2019 to June 2023 were collected.

View Article and Find Full Text PDF

This study aims to investigate the protective effects of docosahexaenoic acid (DHA) combined with bilberry extract (BE) on myopic guinea pigs. In total, 105 healthy pigmented guinea pigs aged 2 weeks were selected and randomly divided into five groups. The normal control (NC) group received no treatment, while the experimental groups wore -6.

View Article and Find Full Text PDF

Effects of capsulorhexis size and position on post-surgical IOL alignment.

Sci Rep

December 2024

Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.

In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!