This study examined tone recognition in five cochlear-implant subjects who were native speakers of Mandarin and used a Nucleus-22 device. Psychophysical experiments were conduced to measure rate discrimination in individual electrodes from the most apical to the most basal electrodes. The rate range was from 100 to 200 Hz, which corresponded to the range of variation in fundamental frequency for the tonal tokens used in this study. Speech recognition experiments were also conducted to measure tone recognition as function of the number of electrodes from a 1-electrode map to a 20-electrode map. Large individual variability was observed for both rate discrimination and tone recognition result: Average rate discrimination ranged between 0.2 and 1.2 (Weber's fraction) whereas tone recognition ranged between 30% and 70% correct. A highly significant correlation was found between rate discrimination and tone recognition with the 20-electrode map, but a non-significant correlation was observed with the 1-electrode map due to a floor effect in tone recognition. The present result supports the hypothesis that both spectral and temporal cues contribute to tone recognition. In addition, the present result shows that current cochlear-implant subjects produced significantly lower performance than acoustic simulations in normal-hearing subjects, suggesting that neither temporal nor spectral cues have been adequately and appropriately extracted and encoded in current cochlear implants. New designs are discussed to improve tone recognition in cochlear implant subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.heares.2004.06.002DOI Listing

Publication Analysis

Top Keywords

tone recognition
36
rate discrimination
16
cochlear-implant subjects
12
recognition
10
recognition cochlear-implant
8
tone
8
1-electrode map
8
20-electrode map
8
discrimination tone
8
recognition result
8

Similar Publications

Objectives: To investigate hearing aid utilization rates among populations with varying hearing aid insurance benefits.

Methods: A retrospective cohort study was performed. A total of 377 patients were included in the study after being identified through consecutive, hearing loss-related otology clinic visits.

View Article and Find Full Text PDF

Background: There is conflicting literature regarding whether cochlear implants (CI) electrode array (EA) selection impacts audiologic outcomes.

Objective: To compare outcomes for the two EA designs, precurved and straight.

Methods: A systematic search of CINAHL, Cochrane Library, PubMed, and SCOPUS was conducted according to PRISMA guidelines.

View Article and Find Full Text PDF

Cryoneurolysis and Quadriplegia: A Case Report on Pain and Severe Spasticity Management.

Arch Rehabil Res Clin Transl

December 2024

Vancouver Island Health Authority, Victoria, BC, Canada.

Spasticity, a common symptom after spinal cord injury, often leads to pain, muscle contracture, and compromised daily activities. Cryoneurolysis, a minimally invasive, drug-free procedure for the treatment of pain, is now gaining recognition for treating spasticity. It involves using an ultrasound-guided probe to freeze and destroy overactive target nerves.

View Article and Find Full Text PDF

NIR-Reflective Black Photonic Films Designed for Effective LiDAR Recognition.

ACS Appl Mater Interfaces

January 2025

Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea.

Conventional dark-tone paints absorb both visible light and near-infrared (NIR) wavelengths, posing a challenge for light detection and ranging (LiDAR) recognition in autonomous driving. To overcome this issue, various chemical and structural coating materials have been explored to selectively reflect NIR. In this study, we newly propose colloidal photonic crystals with a stopband in the NIR range, fabricated through the spontaneous formation of crystalline arrays of silica particles dispersed in a photocurable resin, as a potential solution.

View Article and Find Full Text PDF

Background: The prevalence of hearing loss in infants in India varies between 4 and 5 per 1000. Objective-based otoacoustic emissions and auditory brainstem response have been used in high-income countries for establishing early hearing screening and intervention programs. Nevertheless, the use of objective screening tests in low- and middle-income countries (LMICs) such as India is not feasible.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!