Objectives: We evaluated two microcirculatory function-tests, the Laser Doppler (LD)-Anemometry and the Laser Doppler Imager (LDI)-Flowmetry in their value to further elucidate functional behavior of the "Vibration-induced white finger syndrome" (VWF) and to distinguish between Raynaud's phenomenon (RP) of idiopathic or vibration origin.
Participants And Methods: Ninety-four patients, suffering from RP were studied (78 patients with primary RP and 16 patients with VWF). Measurement of blood cell velocity (BCV) before and after provocation was obtained by nailfold capillary microscopy and an included Laser detector ("Anemometry"). Digital blood flux was recorded by LDI-Flowmetry during a standardized cooling and rewarming thermal challenge.
Results: "Time to peak" of BCV, a measure of maximal reactive hyperemia was longer in VWF in comparison to primary RP (30.37 versus 19.29 sec P < 0.02), respectively.
Conclusion: Based on the fact, that prolongation of reactive hyperemia, an indicator of impaired endothelium-dependent vasodilation is also frequently found in peripheral arterial occlusive disease, it is hypothesized that VWF is not only a microcirculatory vasospastic disorder, but may also be related to atherosclerosis. Anemometry, in association with an appropriate provocation-test, could represent a useful non-invasive method for objectifying diagnosis of VWF in patients with RP.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.mvr.2004.06.006 | DOI Listing |
Equine Vet J
January 2025
Clinic for Horses, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.
Background: Microcirculation is the essential link between macrocirculation and cellular metabolism.
Objectives: To test our hypotheses that microcirculation variables will show a heterogeneous flow pattern during experimental endotoxaemia, and that fluid therapy and noradrenaline (NA) infusion will normalise altered microcirculation variables.
Study Design: In vivo experiments.
Background And Objective: Sickle cell disease (SCD) is a vascular disease that may affect the retina. This study aimed to evaluate differences in average velocity (AV, mm/s), blood flow (BF, μL/min) and vessel diameter (VD, μm) from the temporal retinal arcades in SCD compared to healthy eyes using Doppler optical coherence tomography (DOCT).
Patients And Methods: A cross-sectional study was conducted between 2021 and 2023.
Quant Imaging Med Surg
January 2025
Division of Plastic Surgery, Johns Hopkins University, Baltimore, MD, USA.
Background And Objective: Diabetic neuropathy significantly elevates the risk of foot ulceration and lower-limb amputation, underscoring the need for precise assessment of tissue perfusion to optimize management. This narrative review explores the intricate relationship between sympathetic nerves and tissue perfusion in diabetic neuropathy, highlighting the important role of autonomic neuropathy in blood flow dynamics and subsequent compromises in tissue perfusion. The consequences extend to the development of diabetic peripheral neuropathy and related foot complications.
View Article and Find Full Text PDFMicrovasc Res
January 2025
Primary Health Care Center, Department of Health, Medicine and Caring Sciences, Faculty of Medicine and Health Sciences, Linköping University, Linköping, Sweden; Wallenberg Centre for Molecular Medicine, Linköping University, Linköping, Sweden. Electronic address:
Introduction: Little is known about the day-to-day variability of different skin microcirculation parameters, and how this variability is influenced by age and sex. The aim was to examine the day-to-day variability of microcirculatory parameters in relation to age and sex.
Methods: The cutaneous microcirculation was measured using a fiber optic probe integrating laser Doppler flowmetry (LDF) and diffuse reflectance spectroscopy (DRS) to measure oxygen saturation, red blood cell (RBC) tissue fraction, speed-resolved and conventional perfusion.
Ultramicroscopy
January 2025
Christian Doppler Laboratory for Sustainable Hard Coatings at the Department of Materials Science, Montanuniversität Leoben, Franz-Josef-Straße 18, 8700 Leoben, Austria.
The impact of the laser wavelength on accuracy in elemental composition analysis in atom probe tomography (APT) was investigated. Three different commercial atom probe systems - LEAP 3000X HR, LEAP 5000 XR, and LEAP 6000 XR - were systematically compared for a TiN model coating studying the effect of shorter laser wavelengths, especially in the deep ultraviolet (DUV) range, on the evaporation behavior. The findings demonstrate that the use of shorter wavelengths enhances the accuracy in elemental composition, while maintaining similar electric field strengths.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!