A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Misdiagnosis of atrial fibrillation and its clinical consequences. | LitMetric

Purpose: Computer algorithms are often used for cardiac rhythm interpretation and are subsequently corrected by an overreading physician. The purpose of this study was to assess the incidence and clinical consequences of misdiagnosis of atrial fibrillation based on a 12-lead electrocardiogram (ECG).

Methods: We retrieved 2298 ECGs with the computerized interpretation of atrial fibrillation from 1085 patients. The ECGs were reinterpreted to determine the accuracy of the interpretation. In patients in whom the interpretation was incorrect, we reviewed the medical records to assess the clinical consequences resulting from misdiagnosis.

Results: We found that 442 ECGs (19%) from 382 (35%) of the 1085 patients had been incorrectly interpreted as atrial fibrillation by the computer algorithm. In 92 patients (24%), the physician ordering the ECG had failed to correct the inaccurate interpretation, resulting in change in management and initiation of inappropriate treatment, including antiarrhythmic medications and anticoagulation in 39 patients (10%), as well as unnecessary additional diagnostic testing in 90 patients (24%). A final diagnosis of paroxysmal atrial fibrillation based on the initial incorrect interpretation of the ECGs was generated in 43 patients (11%).

Conclusion: Incorrect computerized interpretation of atrial fibrillation, combined with the failure of the ordering physician to correct the erroneous interpretation, can result in the initiation of unnecessary, potentially harmful medical treatment as well as inappropriate use of medical resources. Greater efforts should be directed toward educating physicians about the electrocardiographic appearance of atrial dysrhythmias and in the recognition of confounding artifacts.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjmed.2004.06.024DOI Listing

Publication Analysis

Top Keywords

atrial fibrillation
24
clinical consequences
12
misdiagnosis atrial
8
interpretation
8
fibrillation based
8
computerized interpretation
8
interpretation atrial
8
1085 patients
8
patients 24%
8
patients
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!