Background: The results of clinical trials of rapamycin-eluting stents reduce restenosis have been quite promising. The main purpose of this study was to characterize the in vivo pharmacokinetics of high dose rapamycin (Rapa)-eluting stents in a miniswine coronary model.

Methods: Ten miniswines underwent placement of 18 high dose Rapa-eluting stents in the left anterior descending and right coronary arteries. At the planned times of the 1.5th, 12th, 24th hour, 3th, 7th and 28th day, the animals (n = 1, 1, 2, 2, 2, and 2, respectively) were euthanized after completion of coronary angiography. Blood samples were obtained at 0, 10, 20, 30 minutes; 1, 2, 6, 24 hours; and 3, 7, 28 days to determine systemic Rapa levels. Rapa levels in whole blood, arterial wall, heart, renal and liver tissues were determined by high-performance liquid chromatography/mass spectroscopy.

Results: Peak whole blood concentration (Cmax), time to peak concentration (tmax), elimination half-life (t1/2beta), area under the curve (AUC), and apparent systemic clearance (Cl/F) were (10.91 +/- 1.28) ng/ml, (2.0 +/- 0.2) hours, (7.25 +/- 0.63) hours, (1.15 +/- 0.11) ng x h x ml(-1), and (180 +/- 12) ml x h(-1) x kg(-1), respectively. More than 95% Rapa detected is localized in the coronary artery surrounding the stent and heart.

Conclusion: Stent-based delivery of Rapa via a copolymer stent is feasible and safe. This strategy holds promise for the prevention of stent restenosis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

rapamycin-eluting stents
8
stents miniswine
8
miniswine coronary
8
high dose
8
rapa-eluting stents
8
rapa levels
8
coronary
5
+/-
5
pharmacokinetics rapamycin-eluting
4
stents
4

Similar Publications

For patients with repeated stenosis of autologous arteriovenous fistula, percutaneous transluminal angioplasty (PTA) or bare metal stent placement had limited efficacy. Rapamycin was reported to inhibit neointimal hyperplasia and keep blood vessels patent. In this study, we reported a case with refractory stenosis, i.

View Article and Find Full Text PDF

Coronary stent implantation links to the occurrence of eosinophilia and interstitial pneumonia: a case report and systematic review.

BMC Pulm Med

June 2024

Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital, College of Clinical Medicine, Henan University of Science and Technology, Luoyang, Henan, China.

Background: Rapamycin has been extensively utilized for coating coronary artery stents to reduce the occurrence of restenosis, yet there has been limited research on the potential harms of rapamycin-eluting stents. Herein, We report a case of eosinophilia and interstitial pneumonia caused by a cobalt-based alloy stent eluted with rapamycin.

Case Presentation: The patient was admitted due to fever, cough, and expectoration symptoms.

View Article and Find Full Text PDF

In vitro and in vivo assessment of a bilayered degradable rapamycin-eluting stent for ureteral stricture caused by holmium: YAG laser lithotripsy.

Acta Biomater

December 2023

Department of Urology, the First Affiliated Hospital of China Medical University, Shenyang, 110002, China; Department of Urology, General Hospital of Northern Theater Command, Shenyang, 110840, China. Electronic address:

Ureteral stricture caused by holmium: YAG laser lithotripsy is one of the most challenging issues for urologists. Currently, evidence for rapamycin application in reducing ureterostenosis is not sufficient. This study aimed to assess the inhibition of ureteral stricture of rapamycin-eluting stents in vitro and in vivo.

View Article and Find Full Text PDF

Background: In coronary atherosclerotic disease, the proliferation of intimal smooth muscle cells (SMCs) is regarded as beneficial with respect to stable and unstable plaques, but is thought detrimental in discussions on coronary stent restenosis. To resolve this discrepancy, we focused on the quality, not quantity, of intimal SMCs in coronary atherosclerotic disease.

Methods: Autopsied coronary artery specimens from seven patients implanted with bare metal stents (BMS), three with paclitaxel-eluting stents (PES), and 10 with sirolimus (rapamycin)-eluting stents (SES) were immunostained for SMC markers.

View Article and Find Full Text PDF

A novel glycyrrhizin acid-coated stent reduces neointimal formation in a rabbit iliac artery model.

Front Pharmacol

May 2023

Department of Cardiovascular Medicine, the Second Xiangya Hospital, Central South University, Changsha, Hunan, China.

Most drug-eluting stents (DESs) inhibit intimal hyperplasia but impair re-endothelialization. This study aimed to evaluate in vivo strut coverage and neointimal growth in a new glycyrrhizin acid (GA)-eluting stent. New Zealand White rabbits ( = 20) with atherosclerotic plaques were randomly divided into three groups based on implanted iliac artery stents: bare-metal stents (BMSs), rapamycin-eluting stents, and GA-eluting stents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?