Cardiopulmonary bypass (CPB) induces hemolysis and the activation of the inflammatory and coagulation systems. Several components of the CPB equipment may contribute to such phenomenon. We tested the effects of two differently designed centrifugal pumps (Bio-Pump, Medtronic and Revolution, Cobe) on several markers of hemolysis, coagulation, and inflammation: plasma free hemoglobin,prothrombin fragment 1.2, platelet factor 4, and P-selectin. Twenty patients requiring coronary artery bypass grafting were randomized to undergo CPB with one of the study centrifugal pumps, and 10 experiments (5 for each pump) were performed with a closed loop circuit to assess pumps' performances over 6 circulation hours using human blood. CPB induced a significant elevation of all the tested markers. Neither in the in vivo nor in the in vitro study were significant differences observed between the groups. Because the Revolution centrifugal pump, which was recently designed and distributed, produced results comparable with those obtained with the BioPump, it should be considered as safe as the Bio-Pump to perform clinical CPB.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.mat.0000136514.53139.d0 | DOI Listing |
Artif Organs
January 2025
BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.
View Article and Find Full Text PDFJ Artif Organs
January 2025
Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shinmachi, Suita, Osaka, 5648565, Japan.
This review traces the evolution of centrifugal blood pumps in mechanical circulatory support (MCS) systems. Initially met with concerns over blood damage and thrombus formation, centrifugal pumps have become crucial components in ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) due to their simplified drive mechanisms and adaptability. This paper outlines three generations of centrifugal pump development: first-generation pumps with sealing components, second-generation pumps utilizing pivot bearings, and third-generation pumps employing contactless bearings.
View Article and Find Full Text PDFBioengineering (Basel)
November 2024
Biomedical Research Center, Qatar University, Doha 2713, Qatar.
A comprehensive analysis of in vitro pumps used in cardiovascular research is provided in this review, with a focus on the characteristics of generated flows and principles of flow generations. The cardiovascular system, vital for nutrient circulation and waste removal, generates complex hemodynamics critical for endothelial cell function. Cardiovascular diseases (CVDs) could be caused by the disturbances in these flows, including aneurysms, atherosclerosis, and heart defects.
View Article and Find Full Text PDFAm J Clin Nutr
January 2025
Department of Immunology, University of Manitoba, Winnipeg, Manitoba, Canada; Manitoba Interdisciplinary Lactation Centre (MILC), Children's Hospital Research Institute of Manitoba, Winnipeg, Manitoba, Canada; Department of Pediatrics and Child Health, University of Manitoba, Winnipeg, Manitoba, Canada. Electronic address:
J Biomech Eng
February 2025
Arts et Métiers Institute of Technology, CNAM, LIFSE, Paris F-75013, France.
Blood pumps, critical components in ventricular assist devices and extracorporeal membrane oxygenation systems, are primarily evaluated based on their ability to minimize blood damage through optimized design. Despite extensive research, the impact of impeller blade thickness and the proximity of rotating and stationary surfaces remains insufficiently explored. This study presents a comprehensive analysis, combining experimentally validated numerical simulations with an advanced Lagrangian approach, to compare the hemodynamic and hemolytic performance of three centrifugal pumps.