We have developed a bioabsorbable polyglycolic acid (PGA) tube filled with collagen sponge (PGA-collagen tube) as a nerve connective guide, and compared its effectiveness with that of autograft in terms of nerve regeneration across a gap. The PGA-collagen tube was implanted into 24 beagle dogs across a 15-mm gap in the left peroneal nerve. The right peroneal nerve was reconstructed with the autograft harvested from the left side, as a control. After the surgery, the connective tissue extended from both cut ends in the PGA-collagen tube and connected again at the center. Pathologically, the collagen sponge in the tube provided adequate scaffolding for nerve tissue extension, and the nerve tissue reconnected within 3 weeks. Electrophysiologically, muscle-evoked potentials (MEPs) and compound nerve action potentials (CNAPs) were detected 18 days after the surgery. For up to 6 months postsurgery, CNAPs and somatosensory-evoked potentials (SEPs) on the PGA-collagen side had a shorter latency and larger peak voltage than those on the autograft side. The myelinated axons on the PGA side were larger in diameter than those on the autograft side. It is suggested that the PGA-collagen tube has the potential to be an effective alternative to conventional autografting for the repair of some peripheral nerve defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.brainres.2004.08.040 | DOI Listing |
Case Reports Plast Surg Hand Surg
September 2024
Department of Plastic and Reconstructive Surgery, Nagasaki University Hospital, Nagasaki, Japan.
We herein report a case of traumatic tibial nerve defect involving the ankle joint. A 16-mm-long defect was observed in a 5-mm-diameter tibial nerve. Two 3-mm-inner-diameter PGA-collagen tubes were transferred to the bifurcated tibial nerve.
View Article and Find Full Text PDFJ Pain Res
May 2023
Department of Orthopaedic Surgery, Faculty of Medicine, Saga University, Saga, Japan.
Purpose: This study used a sciatic nerve injury rat model to investigate the short-term effects of a polyglycolic acid (PGA)-collagen tube for nerve injury in continuity.
Materials And Methods: Sixteen female Wistar rats (6-8 weeks) were used, and the left sciatic nerve was crushed with a Sugita aneurysm clip. Sciatic nerve model rats were randomly categorized into two groups (n = 8; control group, n = 8; nerve wrapping group).
J Plast Surg Hand Surg
May 2023
Department of Plastic and Reconstructive Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; Department of Plastic and Reconstructive Surgery, Nagasaki University Hospital, Nagasaki, Japan.
Background: An artificial nerve conduit can interpose the peripheral nerve defect without donor site morbidity. However, treatment outcomes are often unsatisfactory. Human amniotic membrane (HAM) wrapping has been reported to promote peripheral nerve regeneration.
View Article and Find Full Text PDFGynecol Oncol Rep
June 2022
Department of Plastic and Reconstructive Surgery, Nagasaki University Hospital, Japan.
We herein report three cases of obturator nerve injury, which is rare in gynecological surgery. In all cases, it was difficult to suture both nerve ends without tension. Therefore, we used a PGA-collagen tube to interpose the nerve defect.
View Article and Find Full Text PDFJ Bone Joint Surg Am
February 2020
Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan.
Background: For peripheral nerve defects, autografting is considered the therapeutic gold-standard treatment. However, this procedure leads to donor-site morbidity. While various artificial conduits have been recently developed, treatment outcome has been demonstrated to be poorer than that with autograft.