A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Extending the working range of immunoanalysis by exploitation of two monoclonal antibodies. | LitMetric

Extending the working range of immunoanalysis by exploitation of two monoclonal antibodies.

J Agric Food Chem

Technische Universität München, Wissenschaftszentrum Weihenstephan, Lehrstuhl für Okologische Chemie und Umweltanalytik, Weihenstephaner Steig 23, D-85350 Freising, Germany.

Published: October 2004

A newly established rat monoclonal antibody (mAb) for isoproturon, namely, IOC 10G7, is described. This mAb shows a standard curve for isoproturon in phosphate-buffered saline with a test midpoint of 5.5 +/- 1.8 microg/L (n = 15). In combination with the formerly developed mAb IOC 7E1, IOC 10G7 can be exploited to extend the working range for the analysis of isoproturon. Both antibodies were formatted into a competitive enzyme-linked immunosorbent assay (ELISA), using the same enzyme-tracer. MAb IOC 7E1 and mAb IOC 10G7 have different affinities for the target compound, but the signal-response curves of the single antibodies overlap. Cross-reactivity (CR) patterns of both antibodies are comparable, showing the highest CR for the metabolite 1-(4-isopropylphenyl)-3-methylurea (IOC 10G7, 9%; IOC 7E1, 19%). The system described here includes the combined, but individual, usage of both assays on one microtiter plate, as well as the strategy for mixing the two antibodies for the utilization in one assay. When standards are performed in Milli-Q water, the working range for isoproturon with the individual ELISAs using mAb IOC 7E1 is from 0.01 to 1 microg/L (test midpoint = 0.11 +/- 0.03 microg/L; n = 17) and with IOC 10G7, it is 1-100 microg/L (test midpoint = 10.3 +/- 1.6 microg/L; n = 32). The working range with mixed antibodies is usually on the order of 0.03-30 microg/L (test midpoint = 0.5 +/- 0.2 microg/L; n = 17). These strategies (mAbs individually and mixed) cover a range of 4 and 3 orders of magnitude, respectively. As a demonstration, water samples of different origins and an extract of mixed sediment were analyzed. The advantages of these strategies are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jf0488918DOI Listing

Publication Analysis

Top Keywords

ioc 10g7
20
working range
16
test midpoint
16
mab ioc
16
ioc 7e1
16
+/- microg/l
12
microg/l test
12
ioc
9
midpoint +/-
8
microg/l
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!