Three assays to measure antibodies against Staphylococcus aureus whole cells, lipase and staphylolysin were used to try to discriminate between complicated and uncomplicated S. aureus septicaemia. Sera were examined from 8 patients with S. aureus endocarditis, 23 patients with complicated S. aureus septicaemia, 12 patients with uncomplicated S. aureus septicaemia and 93 febrile non-septicaemic controls. No single assay could distinguish between complicated and uncomplicated S. aureus septicaemia. If the criterion for a positive result is defined as positive antibody level in the anti-lipase ELISA as well as in at least 1 of the other 2 assays, 10/31 patients with S. aureus endocarditis or complicated septicaemia were positive compared to 0/93 non-septicaemic patients and 0/12 patients with uncomplicated S. aureus septicaemia. Therefore, the combined use of serological assays in the diagnosis of complicated S. aureus septicaemia, one of which is the anti-lipase ELISA, is recommended.