Three-dimensional imaging of thoracic diseases with multi-detector row CT.

J Med Invest

Department of Radiologic Technology, School of Health Sciences, The University of Tokushima, Tokushima, Japan.

Published: August 2004

The benefits of multi-detector row CT (MDCT) relative to single-detector row helical CT are considerable. Multi-detector row CT allows shorter acquisition times, greater coverage, and superior image resolution. These factors substantially increase the diagnostic accuracy of the examination. Three-dimensional (3D) volume data from MDCT provides various unique applications on thoracic diseases. These includes isotropic viewings, use of multiplanar reformation (MPR), maximum and minimum intensity projections (MIP and minIP), and volume rendering performed from external and internal perspectives allowing the user to "fly around" and "fly through" the structures. Recent advances in 3D volume rendering put real-time, interactive virtual reality guidance of the procedures such as bronchoscopy and surgery into practice.

Download full-text PDF

Source
http://dx.doi.org/10.2152/jmi.51.163DOI Listing

Publication Analysis

Top Keywords

multi-detector row
12
thoracic diseases
8
volume rendering
8
three-dimensional imaging
4
imaging thoracic
4
diseases multi-detector
4
row
4
row benefits
4
benefits multi-detector
4
row mdct
4

Similar Publications

Improvement of image quality of dentomaxillofacial region in ultra-high resolution computed tomography: A phantom study.

Dentomaxillofac Radiol

November 2024

Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3‑1‑1 Maidashi, Higashi‑ku, Fukuoka, 812‑8582, Japan.

Objectives: The purpose of this study was to compare the image quality of ultra-high-resolution computed tomography (U-HRCT) with that of conventional multi-detector row CT (convCT) and demonstrate its usefulness in the dentomaxillofacial region.

Methods: Phantoms were helically scanned with U-HRCT and convCT scanners using clinical protocols. In U-HRCT, phantoms were scanned in super-high-resolution (SHR) mode, and hybrid iterative reconstruction (HIR) and filtered-back projection (FBP) techniques were performed using a bone kernel (FC81).

View Article and Find Full Text PDF

Background: Peripheral arterial disease (PAD) of the lower limbs is caused by atherosclerotic occlusive disease in which narrowing of arteries reduces blood flow to the lower limbs. PAD is common; it is estimated to affect 236 million individuals worldwide. Advanced age, smoking, hypertension, diabetes and concomitant cardiovascular disease are common factors associated with increased risk of PAD.

View Article and Find Full Text PDF

A retrieval of relevant literature on hepatic nodular lesions, gastric cancer (GC), and Crohn's disease (CD) was conducted from Chinese and English databases. Meta-analysis was performed using Review Manager 5.4 software and the MIDAS package in Stata 18.

View Article and Find Full Text PDF

Objectives: To assess the relationships between longitudinal fluoride intakes and bone densitometry outcomes in young adults.

Methods: Data were analyzed from the Iowa Fluoride Study and Iowa Bone Development Study, which followed 1,882 infants from birth in 1992. Daily fluoride intakes were assessed using detailed questionnaires sent every 1.

View Article and Find Full Text PDF

Depiction rate of feeding arteries of renal cell carcinoma on four-dimensional computed tomography angiography.

Jpn J Radiol

June 2024

Department of Radiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama, 700-8558, Japan.

Purpose: To retrospectively evaluate the depiction rate of feeding arteries in biopsy-proven clear cell renal cell carcinoma (CCRCC) on four-dimensional computed tomography angiography (4D-CTA) images.

Materials And Methods: This study included 22 patients with 22 CCRCC and 30 feeding arteries treated with transcatheter renal artery embolization. The depiction rate of the feeding arteries on preprocedural 4D-CTA was evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!