A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simple, quantitative body surface potential map parameters in the diagnosis of remote Q wave and non-Q wave myocardial infarction. | LitMetric

Background: Body surface potential mapping has been shown to be a useful tool in the diagnosis and localization of remote non-Q wave and Q wave myocardial infarction, but human expertise is required to interpret the maps.

Objective: To identify quantitative body surface potential mapping parameters that could enable a computer-based diagnosis.

Methods: Body surface isopotential maps (63 unipolar leads) were recorded in 86 patients with remote Q wave and 71 patients with remote non-Q wave myocardial infarction. Twenty-four healthy adults served as control subjects. Myocardial infarctions were classified using standard electrocardiogram leads in the acute and chronic phases, and were validated by coronary angiography, ventriculography and thallium scintigraphy.

Results: Two simple quantitative parameters with high diagnostic power were identified: the time interval between the peak minimum and the peak maximum potentials (time-shift), and the ratio of these potentials (maximum to minimum ratio [max/min]). Both parameters showed significant differences between infarction patients and normal control subjects, and optimum cut-off values were determined using receiver operating characteristic curves (anterior infarction: time-shift of -4 ms or less, max/min of 0.6 or less; posterior infarction: time-shift of 8 ms or greater, max/min of 1.25 or greater). The sensitivities of the two parameters were 100% and 97%, and the specificities were 99% and 100%, respectively, in the anterior Q wave infarction group, compared with sensitivities of 88% and 100%, and specificities of 94% and 95%, respectively, in the posterior Q wave infarction group. In the anterior non-Q wave infarction group, sensitivity was 35% for both parameters, specificity was 100% for both parameters, and only infarctions associated with a low ejection fraction were detected, indicating that infarction size may influence the power of the tests.

Conclusions: Time-shift and max/min are two new, simple, powerful parameters for infarction diagnosis and may also be suitable for automated, computer-based processing.

Download full-text PDF

Source

Publication Analysis

Top Keywords

body surface
16
non-q wave
16
surface potential
12
wave myocardial
12
myocardial infarction
12
wave infarction
12
infarction group
12
infarction
11
wave
9
simple quantitative
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!