This study was designed to investigate the effects of propofol, sevoflurane and position changes on respiratory mechanics. Forty patients scheduled for thyroid surgery were divided randomly into two groups; those receiving sevoflurane (group S) (n=20), and those receiving TIVA propofol (group P) (n=22). Dynamic compliance (Cdyn), peak inspiratory pressure (PIP), and respiratory resistance (Rr) values were recorded with a VenTrak respiratory monitor (Novometrix Inc. USA) at three time instances. The first measurement was done immediately after the beginning of ventilation and before the inhalation agent was initiated (Induction). Second measurement was done after 5 minutes of thyroid position (Thyroid) (ventilation with 1 MAC sevoflurane concentration or propofol infusion at the rate of 6 mg/kg/h). The third measurement was performed 5 minutes after end of surgery in the supine position (Supine) Blood gases were measured at the three time instances. Respiratory mechanics did not change in the P group (51 +/- 13, 46 +/- 11, 48 +/- 10 mL/cmH2O) at Induction, Thyroid and Supine positions). In the S group, dynamic compliance measurements showed changes statistically significant in the supine position (52 +/- 6 mL/cmH2O)) when compared to Induction (47 +/- 9 mL/cmH2O) and Thyroid position (47 +/- 6 mL/cmH2O) measurements (p<0.05). When the groups were compared with each other, there was no significant difference whatsoever at all periods (p>0.05). His concluded that sevoflurane, propofol and position changes exhibit similar effects on respiratory mechanics and blood gases at described dose and concentration.
Download full-text PDF |
Source |
---|
Crit Care
January 2025
Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, Guangzhou, China.
Background: Despite the physiological advantages of positive end-expiratory pressure (PEEP), its optimal utilization during one-lung ventilation (OLV) remains uncertain. We aimed to investigate whether individualized PEEP titration by lung compliance is associated with a reduced risk of postoperative pulmonary complications during OLV.
Methods: We searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials until April 1, 2024, to identify published randomized controlled trials that compared individualized PEEP titration by lung compliance with fixed PEEP during OLV.
BMC Pediatr
January 2025
Department of Pulmonology, Tianjin Children's Hospital (Children's Hospital of Tianjin University), Machang compus, 225 Machang Road, Hexi District, Tianjin, 300074, China.
Background: Foreign body inhalation is rare in older children, often leading to underdiagnosis and delayed treatment. Most cases involve a single foreign body, but instances of multiple foreign bodies are exceedingly uncommon. This report presents a case of an elder child who inhaled two pen caps, emphasizing the need for clinical vigilance and thorough medical history collection.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
Background: Flail chest (FC) injuries are segmental osseous injuries of the thorax that typically result from high-energy blunt trauma and regularly occur in multiple trauma (MT) patients. FC injuries are associated with paradoxical chest wall movements and, thus, have a high risk of respiratory insufficiency or even death. An increasing number of studies recommend an early surgical stabilization of FC injuries, but a definite trigger that would indicate surgery has, thus far, not been identified.
View Article and Find Full Text PDFJ Sep Sci
January 2025
Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Gdańsk, Poland.
Interest in obstructive sleep apnea is rising due to its neurocognitive and cardiovascular impacts, including systemic hypertension, myocardial infarction, and cerebrovascular events. Obstructive sleep apnea diagnosis can be suggested through symptoms like snoring, daytime sleepiness, and physical signs like increased neck circumference; however, overnight polysomnography is recommended to confirm. Exhaled breath condensate has emerged as a novel, noninvasive technique for biomarker sample collection.
View Article and Find Full Text PDFWearable Technol
November 2024
BruBotics, Vrije Universiteit Brussel, Brussels, 1050, Belgium.
Advancements in wearable robots aim to improve user motion, motor control, and overall experience by minimizing energetic cost (EC). However, EC is challenging to measure and it is typically indirectly estimated through respiratory gas analysis. This study introduces a novel EMG-based objective function that captures individuals' natural energetic expenditure during walking.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!