A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vitro atrial flow dynamics: normal conditions versus atrial fibrillation. | LitMetric

In vitro atrial flow dynamics: normal conditions versus atrial fibrillation.

J Biomech

Cardiovascular Biomechanics Team, IRPHE-UMR CNRS 6594, EGIM, I.M.T., Technopôle de Château-Gombert, 13383 Marseilles 13, France.

Published: November 2004

Aims: The flow dynamics in the atrium is poorly described. The reasons are principally due to the complicated geometry of the cavity and its contractility. The present in vitro study focuses on the description of the flow in the left atrium in normal conditions (NC) and in atrial fibrillation (AF). The final objective is to give leads to understand, from the hemodynamic point of view, complications in case of AF.

Methods And Results: An atrio-ventricular dual activation system is used to simulate physiological flow in the left atrium. The cavities are compliant and transparent. Velocity measurements are performed with Particle Image Velocimetry. Systolic peak of the pulmonary venous flow is about 0.4 m s(-1) and diastolic peak 0.6 m s(-1) in magnitude. Vortices appear during diastasis and systole and are of normal size and duration. In early and late diastole, the ventricular filling (in NC and AF) and the atrial contraction (in NC only) create a characteristic flow pattern that consists in directed flow towards the mitral valve. In AF an increased resident time (500 ms versus 300 ms) and a slow helical flow pattern (about 0.1 m s(-1)), similar to what is measured using ultrasound echocardiography are observed.

Conclusion: This study uses atrial flow dynamics description to help understand why thromboembolisms occur in AF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2004.01.026DOI Listing

Publication Analysis

Top Keywords

flow dynamics
12
flow
9
atrial flow
8
normal conditions
8
atrial fibrillation
8
flow left
8
left atrium
8
flow pattern
8
vitro atrial
4
dynamics normal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!