Electronic portal imaging devices (EPIDs) are being increasingly employed to make therapy verification and dose measurements in the clinic. In this work, we investigate the use of an amorphous silicon (a-Si) EPID to verify the accuracy of compensator fabrication and mounting. Compensator thickness estimates on a two-dimensional grid were calculated from the primary component of transmission obtained by subtracting a modeled scatter component from the total transmission measured with the EPID. The primary component was related to the thickness via an exponential relation that includes beam hardening. Implementation of the method involved determination of: (i) a calibration curve relating EPID pixel values to energy fluence for open and attenuated fields, which was found to be linear for open fields but to have a small quadratic component for attenuated beams; (ii) EPID scatter factors to account for field size effects, which exhibited a small dependence on compensator thickness and field size; (iii) the attenuation coefficient of the steel shot compensator material, which varied slightly with off-axis distance and field size, and (iv) an analytical model to predict scatter from the compensator, which was calculated to be <4% at the standard EPID imaging distance of 140 cm. Thickness distributions were then measured for several types of attenuators including flat, test, and clinical compensators. Although uncertainties associated with compensator manufacturing were non-negligible and made assessment of thickness measurement uncertainty difficult, we estimate the latter to be approximately 0.5 mm for steel shot compensators of thickness <4 cm.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.1767694 | DOI Listing |
Introduction: Kinematic alignment (KA) in total knee arthroplasty (TKA) is by definition a pure femoral resurfacing procedure aiming to restore the individual prearthritic anatomy. However, when a 2 mm compensation is systematically used on the worn side, the variability in cartilage thickness in the unworn compartment might alter the accuracy of the technique. This study aimed to validate two intraoperative femoral cartilage thickness measurement techniques by comparing them to the photographic method, which measures cartilage thickness through pixel analysis of bone-cut images.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Plastic, Reconstructive and Aesthetic Surgery and Hand Surgery, Centre Hospitalier Universitaire Vaudois (CHUV), 1011 Lausanne, Switzerland.
: Combining autologous fat grafting with implant placement is meant to improve the quality of implant-based breast reconstruction. The present study explores the concept of multi-stage composite breast reconstruction with repeated sessions of autologous fat grafting to increase mastectomy flap thickness and provide better pre-pectoral implant coverage. : Twenty-five consecutive patients underwent bilateral multi-stage composite expander-to-implant breast reconstruction and reverse expansion from August 2020 to April 2024.
View Article and Find Full Text PDFDent J (Basel)
January 2025
Department of Oral Surgery, Faculty of Dental Medicine, Medical University of Varna, 9002 Varna, Bulgaria.
Post-extraction ridge resorption is an inevitable phenomenon that cannot be eliminated but is significantly reduced using additional surgical techniques known as socket preservation. They aim to create favorable conditions for implant placement and prosthetic restoration. This study aims to assess the effect of socket sealing (SS) with free gingival grafts on the vertical resorption of socket walls at the premolar and molar regions over 3 months.
View Article and Find Full Text PDFZhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
The Third Orthopedic Department, the First Affiliated Hospital of Harbin Medical University, Harbin Heilongjiang, 150001, P. R. China.
Objective: To measure and analyze the relationships among the posterior tibial slope (PTS), meniscal slope (MS), and meniscus posterior horn thickness (MPHT) of the medial and lateral tibial plateau in healthy people and patients with anteromedial osteoarthritis (AMOA) in Heilongjiang province, so as to provide reference basis for appropriate tibial osteotomy and prosthesis placement angles in knee joint surgeries.
Methods: A retrospective collection of imaging data from knee joint MRI examinations conducted prior to AMOA for various reasons was performed. A total of 103 healthy individuals (healthy group) and 30 AMOA patients (AMOA group) were included.
Poult Sci
January 2025
Department of Animal Biosciences, University of Guelph, Guelph, ON, N1G 2W1, Canada. Electronic address:
The effects of lifetime feeding of hydrolyzed yeast (HY) to broiler breeders (BB) on egg production, egg quality, and hatchling attributes were investigated. The birds were selected from two groups reared on diets with or without 0.05 % HY from hatch.