Measurement of the macular pigment optical density (MPOD) by heterochromatic flicker photometry (HFP) is accomplished by viewing a small circular stimulus that alternates between a test wavelength that is absorbed by the MP (typically--blue, 460 nm) and a reference wavelength that is not absorbed (typically-green, 540 nm). Flicker observed by the subject is reduced to a null point by adjusting the intensity of the former while viewing the stimulus centrally, and then peripherally. A higher intensity, I, of the blue component of the stimulus is needed under central viewing conditions owing to attenuation by the MP. The MPOD at the test wavelength is given by log (Icentral/Iperipheral). Variation of the test wavelength has been used to measure the MPOD spectrum. This in vitro MPOD spectrum matches that of the carotenoids present in the macular region of the retina and demonstrates the validity and specificity of this methodology. The distribution of MPOD in the retina can be determined with HFP using a series of annular stimuli of different diameters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.abb.2004.04.003 | DOI Listing |
Nanomaterials (Basel)
December 2024
State Key Laboratory of Integrated Optoelectronics, College of Electronic Science & Engineering, Jilin University, No. 2699 Qianjin Street, Changchun 130012, China.
A silica waveguide thermo-optic mode switch with small radius bimodal S-bends is demonstrated in this study. The cascaded multimode interference coupler is adopted to implement the E and E mode selective output. The beam propagation method is used in design optimization.
View Article and Find Full Text PDFGels
November 2024
Departamento de Química, Facultad de Ciencias Naturales, Matemáticas y del Medio Ambiente, Universidad Tecnológica Metropolitana, Santiago 7800003, Chile.
The preparation of sophisticated hierarchically structured and cytocompatible hydrogel scaffolds is presented. For this purpose, a photosensitive resin was developed, printability was evaluated, and the optimal conditions for 3D printing were investigated. The design and fabrication by additive manufacturing of tailor-made porous scaffolds were combined with the formation of surface wrinkled micropatterns.
View Article and Find Full Text PDFDent J (Basel)
November 2024
Department of Oral Surgery of the Institute of Dentistry, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119048 Moscow, Russia.
: Impacted third molar extraction with a scalpel and rotary instruments is one of the most traumatic surgeries in dentistry. Therefore, it is necessary to discover less traumatic methods and instruments to reduce the risk of postoperative complications. : This study is reported in accordance with the CONSORT guidelines.
View Article and Find Full Text PDFClin Oral Investig
December 2024
Department of Orthodontics, Faculty of Dentistry, Kurdistan University of Medical Sciences, Sanandaj, Iran.
Introduction: This study aims to determine if intraoral 850 nm LED irradiation could reduce the duration of lower anterior crowding alignment.
Methods: In a parallel-designed, randomized controlled clinical trial 60 patients with 2 to 6 mm of lower incisor crowding who need non-extraction treatment, were randomly assigned to the intervention and control groups by block randomization (36 females, 24 males, mean age: 19.93 ± 3.
Methods Mol Biol
December 2024
Flinders Health and Medical Research Institute (FHMRI), College of Medicine and Public Health, Flinders University, Bedford Park, SA, Australia.
Optogenetic experiments rely on the controlled delivery of light to diverse biological systems. Impressive devices have been recently developed to stimulate cells and small animals with multiple wavelengths and intensities. However, existing hardware solutions are often limited to a single sample holder, and their design and cost can further limit scalability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!