We have developed sparsely cross-linked "nanogels", subcolloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel replaceable DNA sequencing matrixes for capillary and microchip electrophoresis. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and a low percentage (approximately 10(-4) mol %) of N,N-methylene bisacrylamide (Bis). Nanogels and nanogel networks were characterized by multiangle laser light scattering and rheometry, respectively, and tested for DNA sequencing in both capillaries and chips with four-color LIF detection. Typical nanogels have an average radius of approximately 230 nm, with approximately 75% of chains incorporating a Bis cross-linker. The properties and performance of nanogel matrixes are compared here to those of a linear polyacrylamide (LPA) network, matched for both polymer weight-average molar mass (M(w)) and the extent of interchain entanglements (c/c). At sequencing concentrations, the two matrixes have similar flow characteristics, important for capillary and microchip loading. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, substantially longer average read lengths are obtained under standard conditions with the nanogel matrix at a 98.5% accuracy of base-calling (for CE: 680 bases, an 18.7% improvement over LPA, with the best reads as long as 726 bases, compared to 568 bases for the LPA matrix). We further investigated the use of the nanogel matrixes in a high-throughput microfabricated DNA sequencing device consists of 96 separation channels densely fabricated on a 6-in. glass wafer. Again, preliminary DNA sequencing results show that the nanogel matrixes are capable of delivering significantly longer average read length, compared to an LPA matrix of comparable properties. Moreover, nanogel matrixes require 30% less polymer per unit volume than LPA. The addition of a small amount of low molar mass LPA or ultrahigh molar mass LPA to the optimized nanogel sequencing matrix further improves read length as well as the reproducibility of read length (RSD < 1.6%). This is the first report of a replaceable DNA sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrixes appropriately matched for molar mass and the extent of interchain entanglements. These results could have significant implications for the improvement of microchip-based DNA sequencing technology.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac049721xDOI Listing

Publication Analysis

Top Keywords

dna sequencing
28
nanogel matrixes
16
molar mass
16
read length
12
sequencing
9
sparsely cross-linked
8
matrixes
8
linear polyacrylamide
8
replaceable dna
8
capillary microchip
8

Similar Publications

Background: Familial hemiplegic migraine (FHM) types 1-3 are associated with protein-altering genetic variants in , and , respectively. These genes have also been linked to epilepsy. Previous studies primarily focused on phenotypes, examining genetic variants in individuals with characteristic FHM symptoms.

View Article and Find Full Text PDF

Carcinogenesis often involves significant alterations in the cancer genome, marked by large structural variants (SVs) and copy number variations (CNVs) that are difficult to capture with short-read sequencing. Traditionally, cytogenetic techniques are applied to detect such aberrations, but they are limited in resolution and do not cover features smaller than several hundred kilobases. Optical genome mapping (OGM) and nanopore sequencing [Oxford Nanopore Technologies (ONT)] bridge this resolution gap and offer enhanced performance for cytogenetic applications.

View Article and Find Full Text PDF

vClean: assessing virus sequence contamination in viral genomes.

NAR Genom Bioinform

March 2025

Department of Life Science and Medical Bioscience, Graduate School of Advanced Science and Engineering, Waseda University, 2-2 Wakamatsu-cho, Shinjuku-ku, Tokyo 162-8480, Japan.

Recent advancements in viral metagenomics and single-virus genomics have improved our ability to obtain the draft genomes of environmental viruses. However, these methods can introduce virus sequence contaminations into viral genomes when short, fragmented partial sequences are present in the assembled contigs. These contaminations can lead to incorrect analyses; however, practical detection tools are lacking.

View Article and Find Full Text PDF

Whole-genome automated assembly pipeline for strains from reference, and clinical samples using the integrated CtGAP pipeline.

NAR Genom Bioinform

March 2025

Departments of Medicine and Pediatrics, Division of Infectious Diseases and Global Health, University of California San Francisco School of Medicine, 550 16th Street, 4th Floor Mission Hall, San Francisco, CA, 94158, USA.

Whole genome sequencing (WGS) is pivotal for the molecular characterization of ()-the leading bacterial cause of sexually transmitted infections and infectious blindness worldwide. WGS can inform epidemiologic, public health and outbreak investigations of these human-restricted pathogens. However, challenges persist in generating high-quality genomes for downstream analyses given its obligate intracellular nature and difficulty with propagation.

View Article and Find Full Text PDF

Advancements in DNA sequencing technology have facilitated the generation of a vast number of DNA sequences, posing opportunities and challenges for constructing large phylogenetic trees. DNA barcode sequences, particularly COI, represent extensive orthologous sequences suitable for phylogenetic analysis. Phylogenetic placement analysis offers a promising method to integrate COI data into tree-building efforts, yet the impacts of backbone tree completeness and species composition remain under-explored.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!