Background: Hemodialysis (HD) patients present an immunodeficiency that is mainly related to the defect of cell-mediated immunity. We have previously shown the polarisation of T-helper cells toward the phenotype in HD treatment with cuprophan membrane. In the present study, we have examined the effect of a Vitamin E-coated dialyser (Excebrane, VE) on the activity of the two Th subsets.

Methods: We studied 8 healthy controls and 10 patients on RDT for at least 6 months with cellulose membrane (AC), then switched to HD-VE. Blood was collected from HD patients while on treatment with AC, and after 1 year of treatment with VE. CD4+ cells were isolated from peripheral blood mononuclear cells (PBMC) by negative selection, treating PBMC with a cocktail of anti-CD8, -CD16, -CD19, -CD36 and -CD56 antibodies labelled with magnetic beads, and passing them through a magnetic field. The collected Th cells were cultured for 48 h with and without phytohemagglutinin (PHA). IFNgamma and IL-4 were measured in the supernatant using the ELISA assay.

Results: The constitutive release of IL-4 by CD4+ cells was abated significantly by treatment with VE. IFNgamma released by mitogen-stimulated CD4+ recovered with VE.

Conclusions: This study demonstrates that treatment with vitamin E-coated dialyser improves the defect of PBMC function associated with cellulose membrane dialyser consisting of altered spontaneous and mitogen-stimulated cytokine release. The effects of vitamin E-coated filter, in particular the recovery of reactive IFNgamma production by Th1 cells and the restriction of spontaneous IL-4 release by Th2 cells may have clinical importance.

Download full-text PDF

Source

Publication Analysis

Top Keywords

vitamin e-coated
12
hemodialysis patients
8
e-coated dialyser
8
cellulose membrane
8
cd4+ cells
8
cells
7
treatment
5
[changes th1/th2
4
th1/th2 balance
4
balance hemodialysis
4

Similar Publications

Background: We investigated whether the condition of the inner surface of hollow fibers affects the blood compatibility of hemodialyzers.

Methods: We used scanning probe microscope/atomic force microscopy (SPM/AFM) to investigate the height of the swelling and flexible layers (thickness and softness) on the inner surfaces of the hollow fibers. Next, we tested the blood compatibility between dialyzers comprising a hollow fiber membrane, in which the other dialyzers, except for PVP, were additionally coated using PS membranes coated with other materials.

View Article and Find Full Text PDF

Continuous renal replacement therapy with vitamin E-coated polysulfone hemofilter reduces inflammatory responses in a porcine lipopolysaccharide-treated model.

Ther Apher Dial

February 2025

Medical Technology and Material Laboratory, Research and Business Development Division, Asahi Kasei Medical Co., LTD., Shizuoka, Japan.

Introduction: Biological invasions may promote the onset of systemic inflammatory response syndrome in patients eligible for continuous renal replacement therapy (CRRT), leading to poor prognosis. Hence, we aimed to examine the inflammatory reactions in circulation using vitamin E-coated polysulfone hollow fiber membrane (ViLIFE).

Methods: Lipopolysaccharides were intravenously administered to pigs (2 μg/kg/30 min) to establish an acute inflammation model.

View Article and Find Full Text PDF

A chronic intermittent haemodialysis pig model for functional evaluation of dialysis membranes.

Int J Artif Organs

May 2024

M&M Collaboration Research Laboratory, Department of Medical Environment Innovation, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan.

Performance evaluation of new dialysis membranes is primarily performed in vitro, which can lead to differences in clinical results. Currently, data on dialysis membrane performance and safety are available only for haemodialysis patients. Herein, we aimed to establish an in vivo animal model of dialysis that could be extrapolated to humans.

View Article and Find Full Text PDF

The development of biocompatible membranes, aiming to limit the inflammatory response, oxidative stress, and coagulability during hemodialysis, has been an important step in reducing dialysis-related adverse outcomes. This includes a reduction in the risk of clotting of the extracorporeal circuit, thus enabling hemodialysis with a reduced dose or even without systemic anticoagulant drugs in patients with an increased bleeding risk. In this article, we summarize the in vitro research and clinical evidence on the antithrombotic properties of vitamin E- and heparin-coated membranes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!