Thermoluminescence dosimetry in mixed neutron/gamma radiation beam.

Radiat Prot Dosimetry

Karmanos Cancer Institute and Wayne State University, 3990 John R. Street, Detroit, MI 48201, USA.

Published: December 2004

Miniature CaF2:Tm (TLD-300) were adopted for dosimetry in a mixed neutron/gamma beam produced by the Detroit superconducting cyclotron. A method utilizing the linear relationship between the ratios of the areas under the low and high temperature peaks of the glow curve and the ratios of gamma dose to total dose (Dgamma/DT) in d(48.5)+Be fast-neutron beam was applied for both the gamma component and the total dose measurements. The detectors were grouped based on their response to uniform 60Co dose. Within each group the ratio of the peak areas of the glow curve demonstrated uniformity and stability better than 1.5% (one standard deviation). The parameters of the linear regression between the fractional gamma component in the neutron beam and the ratio of peak areas were derived from measurements at locations with predetermined Dgamma/DT. The method was applied to measure the transmission through the existing multi-rod and newly designed multi-leaf collimators.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/nch162DOI Listing

Publication Analysis

Top Keywords

dosimetry mixed
8
mixed neutron/gamma
8
glow curve
8
total dose
8
gamma component
8
ratio peak
8
peak areas
8
thermoluminescence dosimetry
4
neutron/gamma radiation
4
beam
4

Similar Publications

Physicochemical properties and biological interaction of calcium silicate-based sealers - in vivo model.

Clin Oral Investig

January 2025

Department of Restorative Dentistry - Endodontics, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil.

Objectives: To investigate volumetric changes, in vivo biocompatibility, and systemic migration from eight commercial endodontic sealer materials in paste/paste, powder/liquid, and pre-mixed forms.

Materials And Methods: The sealers AH Plus Bioceramic, AH Plus Jet, BioRoot RCS, MTApex, Bio-C Sealer, Bio-C Sealer Ion+, EndoSequence BC Sealer and NeoSEALER Flo were studied. After characterisation by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), Raman spectroscopy and X-ray diffractometry (XRD), tubes were implanted in Wistar rats' alveolar bone and subcutaneous tissues.

View Article and Find Full Text PDF

Evaluating Cost-effectiveness and Mixing Efficacy for Elastomeric and Temporary Restorative Material Using Two Mixing Tips: A SEM-EDS Analysis.

J Contemp Dent Pract

September 2024

Department of Prosthodontics and Crown & Bridge, Bharati Vidyapeeth Deemed to be University, Dental College and Hospital, Pune, Maharashtra, India, ORCID: https://orcid.org/0009-0008-7338-1699.

Aim: This study aimed to compare the mixing efficacy and cost-effectiveness of new T-mixer tips against the standard double helical tips for a light-body elastomeric impression and a temporary/interim restorative material using a scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy.

Methodology: Automixed samples ( = 16) were divided into four groups of four samples each: Samples that were mixed with Helical tip for elastomer, T-mixer tip for elastomer, Helical tip for interim restorative material, and T-mixer tip for interim restorative material. These samples were then evaluated for SEM analysis.

View Article and Find Full Text PDF

Pacific Proving Grounds-Derived U and U: Potential Tracers for Western North Pacific Ocean Dynamics.

Environ Sci Technol

January 2025

Department of Environmental and Resource Engineering, Technical University of Denmark, DTU Risø Campus, DK-4000 Roskilde, Denmark.

U and U are proven to be useful tracers to investigate upper-ocean hydrodynamics due to their source-specific isotopic ratios and conservative behaviors in the open ocean. However, their application in the Pacific Ocean has been limited by scarce observations and unclear source-term information. Here, we present our observations of U and U in the western North Pacific Subtropical Gyre (NPStG), showing the presence of a source of anthropogenic U featured by a low U/U ratio (∼1 × 10), which is an order of magnitude lower than the global fallout signature (∼2 × 10).

View Article and Find Full Text PDF

Background: Therapeutic radiopharmaceuticals [¹⁷⁷Lu]Lu-DOTA-TATE and [⁹⁰Y]Y-DOTA-TATE are used in peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumors. One of the factors determining the efficacy of such therapy is administering the radiopharmaceutical dose to the patients in a way consistent with treatment planning. This paper evaluates the loss of [¹⁷⁷Lu]Lu-DOTA-TATE and [⁹⁰Y]Y-DOTA-TATE and their mixed doses during the administration to the patient either by direct infusion or by gravity method.

View Article and Find Full Text PDF

The spatial distribution of organics in geological samples can be used to determine when and how these organics were incorporated into the host rock. Mass spectrometry (MS) imaging can rapidly collect a large amount of data, but ions produced are mixed without discrimination, resulting in complex mass spectra that can be difficult to interpret. Here, we apply unsupervised and supervised machine learning (ML) to help interpret spectra from time-of-flight-secondary ion mass spectrometry (ToF-SIMS) of an organic-carbon-rich mudstone of the Middle Jurassic of England (UK).

View Article and Find Full Text PDF