Real-time update of calibration model for better monitoring of batch processes using spectroscopy.

Biotechnol Bioeng

Laboratory of Chemical and Biochemical Engineering, Swiss Federal Institute of Technology (EPFL), CH-1015 Lausanne, Switzerland.

Published: September 2004

In order to reduce the large calibration matrix usually required for calibrating multiwavelength optical sensors, a simple algorithm based on the addition in process of new standards is proposed. A small calibration model, based on 14 standards, is periodically updated by spectra collected on-line during fermentation operation. Concentrations related to these spectra are reconciled into best-estimated values, by considering carbon and oxygen balances. Using this method, fructose, acetate, and gluconacetan were monitored during batch fermentations of Gluconacetobacter xylinus 12281 using mid-infrared spectroscopy. It is shown that this algorithm compensates for noncalibrated events such as production or consumption of by-products. The standard error of prediction (SEP) values were 0.99, 0.10, and 0.90 g/L for fructose, acetate, and gluconacetan, respectively. By contrast, without an updating of the calibration model, the SEP values were 2.46, 0.92, and 1.04 g/L for fructose, acetate, and gluconacetan, respectively. Using only 14 standards, it was therefore possible to approach the performance of an 88-standard-based calibration model having SEP values of 1.11, 0.37, and 0.79 g/L for fructose, acetate, and gluconacetan, respectively. Therefore, the proposed algorithm is a valuable approach to reduce the calibration time of multiwavelength optical sensors.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bit.20153DOI Listing

Publication Analysis

Top Keywords

calibration model
16
fructose acetate
16
acetate gluconacetan
16
sep values
12
g/l fructose
12
multiwavelength optical
8
optical sensors
8
model sep
8
calibration
6
real-time update
4

Similar Publications

Cellular forces regulate an untold spectrum of living processes, such as cell migration, gene expression, and ion conduction. However, a quantitative description of mechanical control remains elusive due to the lack of general, live-cell tools to measure discrete forces between biomolecules. Here we introduce a computational pipeline for force measurement that leverages well-defined, tunable release of a mechanically activated small molecule fluorophore.

View Article and Find Full Text PDF

Objective: Immunotherapy has become an option for the first-line therapy of advanced gastric cancer (GC), with improved survival. Our study aimed to investigate unresectable GC from an imaging perspective combined with clinicopathological variables to identify patients who were most likely to benefit from immunotherapy.

Method: Patients with unresectable GC who were consecutively treated with immunotherapy at two different medical centers of Chinese PLA General Hospital were included and divided into the training and validation cohorts, respectively.

View Article and Find Full Text PDF

Introduction: Ewing sarcoma is a rare paediatric cancer. Currently, there is no way of accurately predicting these patients' survival at diagnosis. Disease type (ie, localised disease, lung/pleuropulmonary metastases and other metastases) is used to guide treatment decisions, with metastatic patients generally having worse outcomes than localised disease patients.

View Article and Find Full Text PDF

Objectives: This study investigated the prognostic role of log odds of negative lymph node/T stage (LONT) and established a nomogram based on LONT to predict the prognosis in colorectal cancer (CRC) patients.

Design: A retrospective cohort study.

Setting And Participants: We enrolled 80 518 CRC patients from the Surveillance, Epidemiology and End Results database between 2010 and 2015.

View Article and Find Full Text PDF

Introduction: Prostate cancer (PCa) is the second most common cancer in men worldwide, with significant incidence and mortality, particularly in Mexico, where diagnosis at advanced stages is common. Early detection through screening methods such as digital rectal examination and prostate-specific antigen testing is essential to improve outcomes. Despite current efforts, compliance with prostate screening (PS) remains low due to several barriers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!