A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization and validation of an enantioselective method for a chiral drug with eight stereo-isomers in capillary electrophoresis. | LitMetric

Optimization and validation of an enantioselective method for a chiral drug with eight stereo-isomers in capillary electrophoresis.

Electrophoresis

Johnson & Johnson, Pharmaceutical Research & Development, Global Analytical Development, Beerse, Belgium.

Published: August 2004

Highly selective capillary electrophoresis (CE) screening methods were applied to find a satisfactory separation of a chiral drug with eight stereoisomeric compounds. The initial separation conditions were further optimized using response surface modelling by applying a Box-Behnken experimental design. This approach resulted in a rapid and efficient optimization of the buffer concentration, the concentration of two cyclodextrins, and the run voltage, in order to obtain final separation conditions of the method. Further optimization and validation of the system in terms of sensitivity and robustness resulted in a method that is suitable for quality control release purposes.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200406031DOI Listing

Publication Analysis

Top Keywords

optimization validation
8
chiral drug
8
capillary electrophoresis
8
separation conditions
8
validation enantioselective
4
enantioselective method
4
method chiral
4
drug stereo-isomers
4
stereo-isomers capillary
4
electrophoresis highly
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!