A novel technique for the detailed size characterization of wear debris.

J Mater Sci Mater Med

Center for Biomedical Engineering, University of Durham, DH1 3LE, UK.

Published: May 2000

The accurate and detailed characterization of artificial joint wear debris is important in determining both the wear rate of prostheses and understanding the role that the debris plays in the development and progression of aseptic loosening. The novel application of low angle laser light scattering (LALLS) to the particle size characterization of ultra high molecular weight polyethylene (UHMWPE) wear debris is described. The results demonstrate that both ex vivo and in vitro origin wear debris samples, at concentrations typical of those produced via an alkali-digestion retrieval route, can be reproducibly analyzed via LALLS. Because the LALLS route enables particle size analysis of the entire debris sample to be acquired non-destructively and whilst in suspension, artefacts associated with filtering, drying and agglomeration of debris are avoided, in contrast to currently used techniques such as filtration and scanning electron microscopy (SEM) observation.

Download full-text PDF

Source
http://dx.doi.org/10.1023/a:1008992911775DOI Listing

Publication Analysis

Top Keywords

wear debris
16
size characterization
8
particle size
8
debris
7
wear
5
novel technique
4
technique detailed
4
detailed size
4
characterization wear
4
debris accurate
4

Similar Publications

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar.

View Article and Find Full Text PDF

Running-In Behavior and Failure Mechanism Between AgCuNi Alloy and Au-Electroplated Layer.

Sensors (Basel)

December 2024

State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China.

To avoid wear and tear of the slip ring due to electrical corrosion, the slip ring needs to undergo the running-in process under atmospheric conditions without current after assembly. To address the urgent demand for long-service capability space conductive slip rings in the aerospace field, the running-in behavior and failure mechanism between the AgCuNi alloy and Au-electroplated layer are investigated using a ball-on-disc tribometer in this paper. The results show that the transfer film composed of Au plays an important role in modifying the friction during the sliding process.

View Article and Find Full Text PDF

Detailed Analysis of the Debris-Fretting Damage Areas on Coated Fuel Cladding.

Materials (Basel)

January 2025

Centrum Výzkumu Řež s.r.o., Hlavní 130, 250 68 Husinec-Řež, Czech Republic.

Fuel failure caused by fretting damage to cladding remains a relevant issue despite decades of research and development aimed at enhancing the physical parameters of fuel. This paper presents the results of experiments conducted at the Research Centre Řež on Zr-1%Nb alloy tube specimens covered with protective coatings made of chromium (Cr) and nitrogen (N) compounds. The experiments involved debris-fretting tests under dry conditions at room temperature as well as microscopic measurements of groove depths.

View Article and Find Full Text PDF

Context: This study employs molecular dynamics simulations to investigate the nanoscale tribological behavior of a single transverse grain boundary in a nickel-based polycrystalline alloy. A series of simulations were conducted using a repetitive rotational friction method to explore the mechanisms by which different grain boundary positions influence variations in wear depth, friction force, friction coefficient, dislocation, stress, and internal damage during repeated friction processes. The results reveal that the grain boundary structure enhances the strength of the nanoscale nickel-based polycrystalline alloy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!