This report documents the development of a new monosaccharide separator column (CarboPac PA20, 3x150 mm) that allows fast, efficient monosaccharide separations with good spacing. It is based on a new chemistry with a reduced resin particle size (from 10 to 6.5 microm). Faster, more efficient separations of glycoprotein monosaccharides with better spacing were achieved across a range of isocratic NaOH concentrations at lower flow rates. Detection sensitivity was improved, enabling routine low to sub pmol monosaccharide determinations. Glycoprotein monosaccharides eluted in less than 10 min at a flow rate of 0.5 ml/min. Furthermore, when used with an AminoTrap guard column, the protein matrix consisting of amino acids and peptides (released by acid hydrolysis of glycoprotein) did not interfere with monosaccharide analysis. Compared to previous CarboPac columns (CarboPac PA1 and CarboPac PA10), the CarboPac PA20 has improved selectivity with respect to glycoprotein monosaccharides. The improved selectivity results in better separation of glucosamine and galactose, enabling the accurate determination of monosaccharide ratios for undergalactosylated glycoproteins. Finally, disposable gold working electrodes that eliminate the possibility of working electrode recession affecting peak area response were used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbbm.2004.01.009DOI Listing

Publication Analysis

Top Keywords

carbopac pa20
12
glycoprotein monosaccharides
12
monosaccharide separator
8
separator column
8
disposable gold
8
improved selectivity
8
carbopac
6
monosaccharide
6
pa20 monosaccharide
4
column electrochemical
4

Similar Publications

An efficient and sensitive analytical method based on high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) was devised for the determination of glucosamine (GlcN) in sodium chondroitin sulfate (CS). Glucosamine (GlcN) is intended as marker of residual keratan sulfate (KS) and other impurities generating glucosamine by acidic hydrolyzation. The latter brings CS and KS to their respective monomers.

View Article and Find Full Text PDF

A simple, accurate, and highly sensitive method was developed for the determination of 13 carbohydrates in polysaccharide of Spirulina platensis based on high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry. Samples were extracted with deionized water using ultrasonic-assisted extraction, and the ultrasound-assisted extraction conditions were optimized by Box-Behnken design. Then the extracted polysaccharide was hydrolyzed by adding 1 mol/L trifluoroacetic acid before determination by high-performance anion-exchange chromatography coupled with pulsed amperometric detection and confirmed by high-performance anion-exchange chromatography coupled with mass spectrometry.

View Article and Find Full Text PDF

A new two-dimensional ion chromatography method was developed to parallelly analyze two different types of samples with the application of valve switching technology-suppressed conductivity and pulsed amperometric analysis system, for concurrent determination of chloride, nitrite, sulfate, nitrate four inorganic anions and gluconate. The first dimensional chromatography was using Ionpac AG18+Ionpac AS18 anion analysis columns with a suppressed conductivity detector for the separation and detection of Cl-, NO2-, SO4(2-) and NO3-. Respectively, the elution was 5 and 20 mmol/L NaOH at an isocratic flow rate of 1.

View Article and Find Full Text PDF

An acetate-hydroxide gradient for the quantitation of the neutral sugar and uronic acid profile of pectins by HPAEC-PAD without postcolumn pH adjustment.

J Agric Food Chem

March 2014

Institute of Food Science and Biotechnology, Chair of Plant Foodstuff Technology, Hohenheim University, Garbenstrasse 25, 70599 Stuttgart, Germany.

An HPAEC-PAD method was developed and validated to quantitate seven neutral sugars and two uronic acids of hydrolyzed pectic polysaccharides without postcolumn pH adjustment. Due to a short gradient phase minimizing the ion concentrations after equilibrating the CarboPac PA20 column with sodium acetate and hydroxide, subsequent isocratic separation of the neutral sugars was characterized by almost baseline resolution of rhamnose and arabinose (1.45 ± 0.

View Article and Find Full Text PDF

Evaluation of a liquid chromatography method for compound-specific δ13C analysis of plant carbohydrates in alkaline media.

Rapid Commun Mass Spectrom

September 2012

Laboratory of Atmospheric Chemistry, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.

Rationale: Isotope analysis of carbohydrates is important for improved understanding of plant carbon metabolism and plant physiological response to the environment. High-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS) for direct compound-specific δ(13)C measurements of soluble carbohydrates has recently been developed, but the still challenging sample preparation and the fact that no single method is capable of separating all compounds of interest hinder its wide-spread application. Here we tested in detail a chromatography method in alkaline media.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?