Stent implantation for coarctation of aorta caused by a Rashkind patent ductus arteriosus umbrella.

Catheter Cardiovasc Interv

Department of Pediatric Cardiology, Schneider Children's Medical Center-Israel, Beilinson Campus, Tel Aviv University, Petach Tikva, Israel.

Published: September 2004

This case demonstrates a novel use of stent implantation for relief of coarctation of the aorta caused by protrusion of a Rashkind patent ductus arteriosus umbrella. Follow-up 3 years after stent implantation shows complete relief of obstruction.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.20128DOI Listing

Publication Analysis

Top Keywords

stent implantation
12
coarctation aorta
8
aorta caused
8
rashkind patent
8
patent ductus
8
ductus arteriosus
8
arteriosus umbrella
8
implantation coarctation
4
caused rashkind
4
umbrella case
4

Similar Publications

Purpose: Treatment of peripheral artery disease (PAD) in the region below the knee (BTK) is dissatisfying as failure of treated target lesions (TLF) is frequent and diagnostic imaging is often challenging. In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.

View Article and Find Full Text PDF

The Management of the Aortic Arch in Type A Aortic Dissection: Replace, Repair with the AMDS, or Leave for Another Day?

J Cardiovasc Dev Dis

January 2025

Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB T6G 2R3, Canada.

Objectives: Acute type A aortic dissection (ATAAD) is a life-threatening condition that requires emergent surgical intervention. Numerous surgical approaches exist for ATAAD, and controversy remains regarding the optimal arch interventions for ATAAD patients. Aortic Arch Interventions: Approaches to ATAAD repair include hemiarch repair or extended arch repairs, including the hemiarch with a hybrid stent implantation, such as the AMDS hybrid Prosthesis, total arch replacement (TAR), and the use of an elephant trunk and frozen elephant trunk.

View Article and Find Full Text PDF

Purpose: To report the occurrence of acute postrenal kidney failure caused by external ureteral obstruction after iliac venous stent placement.

Case Report: A 73-year-old male patient presented with a chronic swelling and feeling of heaviness of his right leg. The presence of venous thrombosis was excluded by duplex ultrasound (DUS).

View Article and Find Full Text PDF

Objective: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs.

Methods: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm), S3 group (high-dose rapamycin-coated stent, 415 µg/mm), and D0 group (bare metal stent). The stent size was 3.

View Article and Find Full Text PDF

Comparison of outcomes with and without intrastent placement during PMS surgery.

Sci Rep

January 2025

Department of Ophthalmology and Visual Science, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku City, 783-8505, Kochi, Japan.

To assess the efficacy of using a nylon suture as a stent in the PreserFlo MicroShunt (PMS) lumen to prevent postoperative hypotony, 59 eyes that underwent PMS implantation with follow-up for > 6 months were analyzed. Patients were divided into no intrastenting (NST) and intrastenting (ST) groups, with the ST group subdivided into 9 - 0 nylon suture fully placed (9 F), 9 - 0 nylon suture placement in only half of the lumen (9 H), 10 - 0 nylon suture fully placed (10 F), and 10 - 0 nylon suture placement in only half of the lumen (10 H). The distribution was as follows: 23 eyes in the NST group, 10 in the 9 F group, 9 in the 9 H group, 11 in the 10 F group, and 6 in the 10 H group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!