A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pseudooctahedral complexes of vanadium(III): electronic structure investigation by magnetic and electronic spectroscopy. | LitMetric

A variety of physical methods has been used to probe the non-Kramers, S = 1, V(III) ion in two types of pseudooctahedral complexes: V(acac)(3), where acac = anion of 2,4-pentanedione, and VX(3)(thf)(3), where thf = tetrahydrofuran and X = Cl and Br. These methods include tunable frequency and high-field electron paramagnetic resonance (HFEPR) spectroscopy (using frequencies of approximately 95-700 GHz and fields up to 25 T) in conjunction with electronic absorption, magnetic circular dichroism (MCD), and variable-temperature variable-field MCD (VTVH-MCD) spectroscopies. Variable-temperature magnetic susceptibility and field-dependent magnetization measurements were also performed. All measurements were conducted on complexes in the solid state (powder or mull samples). The field versus sub-THz wave quantum energy dependence of observed HFEPR resonances yielded the following spin Hamiltonian parameters for V(acac)(3): D = +7.470(1) cm(-1); E = +1.916(1) cm(-1); g(x) = 1.833(4); g(y) = 1.72(2); g(z) = 2.03(2). For VCl(3)(thf)(3), HFEPR detected a single zero-field transition at 15.8 cm(-1) (474 GHz), which was insufficient to determine the complete set of spin Hamiltonian parameters. For VBr(3)(thf)(3), however, a particularly rich data set was obtained using tunable-frequency HFEPR, and analysis of this data set gave the folowing: D = -16.162(6) cm(-1); E = -3.694(4) cm(-1); g(x) = 1.86(1); g(y) = 1.90(1); g(z) = 1.710(4). Analysis of the VTVH-MCD data gave spin Hamiltonian parameters in good agreement with those determined by HFEPR for both V(acac)(3) and VBr(3)(thf)(3) and in rough agreement with the estimate for VCl(3)(thf)(3) (D approximately 10 cm(-1), |E/D| approximately 0.18), together with the finding that the value of D is negative for both thf complexes. The electronic structures of these V(III) complexes are discussed in terms of their molecular structures and the electronic transitions observed by electronic absorption and MCD spectroscopies.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ic0493503DOI Listing

Publication Analysis

Top Keywords

spin hamiltonian
12
hamiltonian parameters
12
pseudooctahedral complexes
8
electronic absorption
8
data set
8
electronic
6
cm-1
6
hfepr
5
complexes vanadiumiii
4
vanadiumiii electronic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!