Purpose: To explore the imaging capabilities of a new commercially available, three-station, 129-cm long, 12-element phased array coil for contrast-enhanced magnetic resonance angiography (CE-MRA) in patients with symptomatic peripheral arterial occlusive disease.

Materials And Methods: Nineteen patients, referred for peripheral CE-MRA, were evaluated using the new three-station coil. For each station four coil elements (two anterior and two posterior to the patient) were used. The expected improvements in signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were used to improve spatial resolution and increase anatomic coverage for the distal two stations compared to our previous protocol. Images obtained in the 19 patients imaged with the new coil were compared to those of the last 19 patients scanned without the use of the new coil. Differences in image quality before vs. after the availability of the new coil were compared in terms of SNR and CNR, subjective interpretability score (SIS), degree of venous enhancement, and anatomic coverage. Images were interpreted by two experienced observers, blinded for imaging technique and each other's results.

Results: Use of the coil enabled acquisition of high resolution peripheral vasculature images in all cases and allowed for substantially smaller voxel sizes (thighs: 5.3 vs. 8.4 mm(3) [-37%]; legs: 1.8 vs. 8.0 mm3 [-78%]) and much shorter acquisition durations in the aortoiliac and thigh stations (aortoiliac: 16 vs. 27 seconds [-41%]; thighs: 11 vs. 23 seconds [-52%]). Acquisition duration in the leg station was prolonged (68 vs. 29 seconds [+134%]). SNR and CNR were significantly higher only in the aortoiliac station using the three-station coil (both: P < 0.001). There were no significant differences in SIS for the aortoiliac and thigh stations (aortoiliac station: observer 1: P = 0.16, observer 2: P = 0.19; thigh station: both observers: P = 0.27). Images acquired with the new coil had significantly higher SIS for the leg station (both observers: P = 0.004). There were no significant differences in venous enhancement between the two protocols for any of the stations (all P > 0.11). In 12/12 (100%) requested cases the entire pedal arch was depicted using the new coil, whereas this was not possible with the old protocol.

Conclusion: The new three-station dedicated peripheral vascular coil allows for much higher resolution imaging in the thigh and leg stations with greater anatomic coverage and substantially improves peripheral MRA quality of the lower leg vasculature.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.20129DOI Listing

Publication Analysis

Top Keywords

coil
12
anatomic coverage
12
phased array
8
array coil
8
contrast-enhanced magnetic
8
magnetic resonance
8
resonance angiography
8
three-station coil
8
coil compared
8
snr cnr
8

Similar Publications

The bacterial infection and oxidative wound microenvironment delay skin repair and necessitate intelligent wound dressings to enable scarless wound healing. The immunoglobulin of yolk (IgY) exhibits immunotherapeutic potential for the potential treatment of antimicrobial-resistant pathogens, while cerium oxide nanoparticles (CeO NPs) could scavenge superoxide dismutase (SOD) and inflammation. The overarching objective of this study was to incorporate IgY and CeO NPs into poly(L-lactide-co-glycolide)/gelatin (PLGA/Gel)-based dressings (P/G@IYCe) for infected skin repair.

View Article and Find Full Text PDF

Controllable Self-Assembly Morphologies of PPV-Based Block Copolymers.

Chemistry

January 2025

Southern University of Science and Technology, Chemistry, 1088 Xueyuan Blvd., Xili, Nanshan District, 518055, Shenzhen, CHINA.

Poly(p-phenylenevinylene) (PPV) is a classic semiconducting π-conjugated polymers with outstanding optical and electronic properties, which shows important applications in the fields of optoelectronic, such as organic light-emitting diodes (OLEDs), organic solar cells (OSCs), and organic field-effect transistors (OFETs). In the working process of the device, the microstate of PPV decides its property. Therefore, it is significant to achieve ordered morphologies based on PPV at micro scale.

View Article and Find Full Text PDF

Impact of Endorectal Coil Use on Extraprostatic Extension Detection in Prostate MRI: A Retrospective Monocentric Study.

Acad Radiol

January 2025

Molecular Imaging Branch, National Cancer Institute, National Institutes of Health, Bethesda, MD (O.T.E., E.C.Y., B.D.S., S.A.H., D.G.G., Y.L., M.J.B., P.L.C., B.T.). Electronic address:

Rationale And Objectives: Accurate preoperative mpMRI-based detection of extraprostatic extension (EPE) in prostate cancer (PCa) is critical for surgical planning and patient outcomes. This study aims to evaluate the impact of endorectal coil (ERC) use on the diagnostic performance of mpMRI in detecting EPE.

Materials And Methods: This retrospective study with prospectively collected data included participants who underwent mpMRI and subsequent radical prostatectomy for PCa between 2007 and 2024.

View Article and Find Full Text PDF

The Role of Artificial Intelligence in Predicting Optic Neuritis Subtypes From Ocular Fundus Photographs.

J Neuroophthalmol

December 2024

Division of Ophthalmology (EB-S, AS, AA-A, AS-B, DW, SS, FC), Department of Surgery, University of Calgary, Calgary, Canada; Department of Biomedical Engineering (CN), University of Calgary, Calgary, Canada; Departments of Neurology (LBDL) and Ophthalmology (LBDL), University of Michigan, Ann Arbor, Michigan; and Department of Clinical Neurosciences (SS, FC), University of Calgary, Calgary, Canada.

Background: Optic neuritis (ON) is a complex clinical syndrome that has diverse etiologies and treatments based on its subtypes. Notably, ON associated with multiple sclerosis (MS ON) has a good prognosis for recovery irrespective of treatment, whereas ON associated with other conditions including neuromyelitis optica spectrum disorders or myelin oligodendrocyte glycoprotein antibody-associated disease is often associated with less favorable outcomes. Delay in treatment of these non-MS ON subtypes can lead to irreversible vision loss.

View Article and Find Full Text PDF

Recent progress in digital microfluidics has revealed the distinct advantages of liquid marbles, such as minimal surface friction, reduced evaporation rates, and non-wettability compared to uncoated droplets. This study provides a comprehensive examination of an innovative technique for the precise, contamination-free manipulation of non-magnetic water liquid marbles (WLMs) carried by a ferrofluid liquid marble (FLM) under the control of direct current (DC) and pulse-width modulation (PWM) magnetic fields. The concept relies on the phenomenon in which an FLM and WLMs form a shared meniscus when placed together on a water surface, causing the WLMs to closely track the magnetically actuated FLM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!