Coarse scales, fine scales, and their interactions in stereo vision.

J Vis

Institute for Sensory Research, Syracuse University, Syracuse, NY 13244-5290, USA.

Published: June 2004

Human stereo vision can resolve remarkably small depth differences between two stimuli, but the smallest resolvable difference is usually that between stimuli located near the plane of fixation. As distance from this plane increases, so does the smallest detectable increment in disparity. We examined this loss of resolution by comparing disparity discrimination thresholds for single-scale and multi-scale stimuli as a function of the pedestal disparity. For single-scale gratings, disparity thresholds display phase constancy; thus, their spatial thresholds vary reciprocally with grating spatial frequency. For multi-scale gratings, with components separated in frequency by two or three octaves, disparity thresholds display two types of interaction between coarse-scale and fine-scale components: facilitation when pedestal disparities are moderate and interference when they are large. The facilitation extends the disparity range that yields the low thresholds associated with fine-scale components, limiting the loss of disparity resolution for multi-scale stimuli.

Download full-text PDF

Source
http://dx.doi.org/10.1167/4.6.8DOI Listing

Publication Analysis

Top Keywords

stereo vision
8
multi-scale stimuli
8
disparity thresholds
8
thresholds display
8
fine-scale components
8
disparity
7
thresholds
5
coarse scales
4
scales fine
4
fine scales
4

Similar Publications

Residual Vision Transformer and Adaptive Fusion Autoencoders for Monocular Depth Estimation.

Sensors (Basel)

December 2024

Institute of Computer and Communication Engineering, Department of Electrical Engineering, National Cheng Kung University, Tainan 701, Taiwan.

Precision depth estimation plays a key role in many applications, including 3D scene reconstruction, virtual reality, autonomous driving and human-computer interaction. Through recent advancements in deep learning technologies, monocular depth estimation, with its simplicity, has surpassed the traditional stereo camera systems, bringing new possibilities in 3D sensing. In this paper, by using a single camera, we propose an end-to-end supervised monocular depth estimation autoencoder, which contains an encoder with a structure with a mixed convolution neural network and vision transformers and an effective adaptive fusion decoder to obtain high-precision depth maps.

View Article and Find Full Text PDF
Article Synopsis
  • Accurate 3D information estimation from images is crucial for computer vision, and while binocular stereo vision is a common approach, it faces challenges with baseline distance affecting reliability.
  • This research proposes a new method that progressively increases the baseline in multiocular vision, introducing a rectification technique that significantly reduces distortion errors in the images.
  • The method enhances disparity estimation accuracy by 20% for multiocular images and demonstrates superior performance through extensive evaluations against existing methods.
View Article and Find Full Text PDF

In diagnosing and treating prostate cancer the flexible bevel tip needle insertion surgical technique is commonly used. Bevel tip needles experience asymmetric loading on the needle's tip, inducing natural bending of the needle and enabling control mechanisms for precise placement of the needle during surgery. Several methods leverage the needles natural bending to provide autonomous control of needle insertion for accurate needle placement in an effort to reduce excess tissue damage and improve patient outcomes from needle insertion intraventions.

View Article and Find Full Text PDF

The study sought to compare the number of cycles (NOS) for the first and second thirty-seconds (FASTS) within 1 min of accommodative facility (AF) and vergence facility (VF) testing to explore possibilities of reducing testing time to 30 s. In this cross-sectional study, a multistage sample of school children (aged 8-17 years) was taken through ocular-visual screening. Eligible participants (586) underwent refraction, stereo-acuity measurement, AF testing using ± 2D lens flippers, and VF testing using 3 BI/12 BO flipper prisms.

View Article and Find Full Text PDF

Autonomous technologies have revolutionized transportation, military operations, and space exploration, necessitating precise localization in environments where traditional GPS-based systems are unreliable or unavailable. While widespread for outdoor localization, GPS systems face limitations in obstructed environments such as dense urban areas, forests, and indoor spaces. Moreover, GPS reliance introduces vulnerabilities to signal disruptions, which can lead to significant operational failures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!