A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

AnDiaTec Salmonella sp. PCR-ELISA for analysis of food samples. | LitMetric

AnDiaTec Salmonella sp. PCR-ELISA for analysis of food samples.

J Food Prot

AnDiaTec GmbH & Co KG, Leibnizstrasse 11, 70806 Kornwestheim, Germany.

Published: August 2004

A commercially available PCR kit (AnDiaTec Salmonella sp. PCR-ELISA) was developed and evaluated for the detection of Salmonella sp. in food samples. The test is based on PCR amplification and hybridization of the amplified DNA to a microtiter plate followed by the detection of PCR product in the manner of an enzyme-linked immunosorbent assay test. The sensitivity and specificity were evaluated first with Salmonella pure cultures and artificially contaminated food samples, including food types for which an inhibition of the PCR reaction was expected. Both experiments proved a very good sensitivity, specificity, and reliability of the test with a very broad range of food types. In a second evaluation study, more than 1,100 food samples of different types were tested in parallel with the PCR method and with the International Standardization Organization 6579 bacteriological reference method. The results of this evaluation study and the results from other experiments on dilutions of artificially contaminated food samples led to the establishment of a positive-negative cutoff value (optical density at 450 nm of more than 0.9) with respect to the conventional bacteriological method. Using this positive-negative cutoff, 98% agreement to the bacteriological method was obtained.

Download full-text PDF

Source
http://dx.doi.org/10.4315/0362-028x-67.8.1585DOI Listing

Publication Analysis

Top Keywords

food samples
20
andiatec salmonella
8
salmonella pcr-elisa
8
sensitivity specificity
8
artificially contaminated
8
contaminated food
8
food types
8
evaluation study
8
positive-negative cutoff
8
bacteriological method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!