Intracoronary stent implantation is a frequently performed procedure in the treatment of stenoses in coronary arteries, but in-stent restenosis occurs in approximately 10% to 15% of patients. A noninvasive diagnostic procedure to evaluate in-stent restenosis would therefore be of great benefit. We investigated the feasibility of assessing stent patency with 16-slice computed tomography. Multislice computed tomography (MSCT) was performed in 22 patients with previously implanted stents. For each stent, assessability was determined and related to stent type and diameter. Subsequently, the presence of significant restenosis was determined in the evaluable stents. In addition, peristent lumina (5 mm proximal and distal to the stent) were evaluated. Conventional angiography in combination with quantitative coronary angiography served as the standard of reference. MSCT was performed successfully in all but 1 patient. Of 65 stents, 50 (77%) were determined assessable. Uninterpretable stents tended to have a thicker strut and/or a smaller diameter. In the evaluable stents, 7 of 9 stenoses were detected and the absence of restenosis was correctly identified in all 41 patent stents, resulting in a sensitivity and specificity of 78% and 100%, respectively. Sensitivity and specificity for the detection of peristent stenosis were 75% and 96%, respectively. In conclusion, MSCT may be useful in the assessment of stent patency and may function as a gatekeeper before invasive diagnostic procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2004.04.057DOI Listing

Publication Analysis

Top Keywords

stent patency
12
computed tomography
12
patency 16-slice
8
16-slice computed
8
in-stent restenosis
8
msct performed
8
evaluable stents
8
sensitivity specificity
8
stent
7
stents
6

Similar Publications

: The parallel stent graft endovascular aortic repair (PGEVAR) technique is an off-the-shelf option used for elective complex abdominal aortic aneurysm repair with acceptable outcome results, as reported so far. The PGEVAR technique, using chimney or periscope parallel grafts, can also be used for patients with ruptured complex abdominal aortic aneurysms. However, only few data about the mid- to long-term outcomes are available.

View Article and Find Full Text PDF

Understanding the Mechanisms of Main Bronchial Compression in Patients with Intracardiac Anomalies.

Ann Thorac Surg Short Rep

September 2024

Department of Pediatric Cardiovascular Surgery, Kanazawa Medical University, Ishikawaken, Japan.

Background: The study focuses on vascular compression of the main bronchus in the aortopulmonary space, examining potential contributors within the same axial plane. Its goal is to uncover mechanisms of bronchial compression in patients with intracardiac anomalies and review surgical outcomes, aiming to enhance future results.

Methods: The morphology and topology of structures within the axial plane of the aortopulmonary space were objectively analyzed, including the sternum, ascending aorta, heart, pulmonary artery, descending aorta, and other relevant elements.

View Article and Find Full Text PDF

A 54-year-old man underwent right S6 segmentectomy for right lung cancer. After discharge, he presented with fever, hemoptysis, and cough, and computed tomography showed an intermediate bronchus fistula. Because direct closure or bronchoplasty was challenging, a Dumon (Novatech) stent was inserted directly into the fistula from the surgical field and covered with an autologous pericardial patch, pedicled mediastinal fat, and intercostal muscle.

View Article and Find Full Text PDF

Purpose: The AVeNEW Post-Approval Study (AVeNEW PAS) follows upon results from the AVeNEW IDE clinical trial and was designed to provide additional clinical evidence of safety and effectiveness using the Covera™ Vascular Covered Stent to treat arteriovenous fistula (AVF) stenoses in a real-world hemodialysis patient population.

Materials And Methods: One hundred AVF patients were prospectively enrolled at 11 clinical trial sites in the USA and treated with the covered stent after angioplasty of a clinically significant target stenosis. The primary safety outcome was freedom from any adverse event that suggests the involvement of the AV access circuit evaluated at 30 days.

View Article and Find Full Text PDF

Purpose: This study assesses the efficacy and safety of Portal Vein Recanalization with Intrahepatic Portosystemic Shunt (PVR-TIPS) in non-cirrhotic patients with chronic portal vein occlusion (CPVO), cavernomatous transformation, and symptomatic portal hypertension (PH) and/or portal vein thrombotic progression.

Material And Methods: Medical records of 21 non-cirrhotic patients with CPVO and portal cavernoma undergoing PVR-TIPS were analyzed. Hemodynamic (intraprocedural reduction in portosystemic pressure gradient), clinical (data on gastrointestinal bleeding, abdominal pain, ascites, and presence of esophageal varices from imaging exams) and technical success (PVR-TIPS) assessed efficacy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!