A bullet signature measurement system based on a stylus instrument was developed at the National Institute of Standards and Technology (NIST) for the signature measurements of NIST RM (Reference Material) 8240 standard bullets. The standard bullets are developed as a reference standard for bullet signature measurements and are aimed to support the recently established National Integrated Ballistics Information Network (NIBIN) by the Bureau of Alcohol, Tobacco and Firearms (ATF) and the Federal Bureau of Investigation (FBI). The RM bullets are designed as both a virtual and a physical bullet signature standard. The virtual standard is a set of six digitized bullet signatures originally profiled from six master bullets fired at ATF and FBI using six different guns. By using the virtual signature standard to control the tool path on a numerically controlled diamond turning machine at NIST, 40 RM bullets were produced. In this paper, a comparison parameter and an algorithm using auto-and cross-correlation functions are described for qualifying the bullet signature differences between the RM bullets and the virtual bullet signature standard. When two compared signatures are exactly the same (point by point), their cross-correlation function (CCF) value will be equal to 100%. The measurement system setup, measurement program, and initial measurement results are discussed. Initial measurement results for the 40 standard bullets, each measured at six land impressions, show that the CCF values for the 240 signature measurements are higher than 95%, with most of them even higher than 99%. These results demonstrate the high reproducibility for both the manufacturing process and the measurement system for the NIST RM 8240 standard bullets.

Download full-text PDF

Source

Publication Analysis

Top Keywords

bullet signature
24
standard bullets
20
measurement system
16
8240 standard
12
signature measurements
12
signature standard
12
standard
10
signature
9
bullets
9
signature measurement
8

Similar Publications

Cranio-facial trauma diagnosis using paleo-proteotyping of a blood sample from Robespierre (1794).

Ann Pharm Fr

December 2024

Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (DMTS), SPI, 30200 Bagnols-sur-Cèze, France.

Tradition has it that the politician Robespierre, a famous tribune of the French Revolution, was lying, wounded in the face by a bullet from a firearm, on an 18th century desk, and left a trace of blood there, before being guillotined the next day (1794). This piece of furniture is now kept in the National Archives (Paris, France). A paleo-proteomic study was carried out on several brown stains on the leather of the desk, which confirmed the human blood nature of the sample, but also identified the protein signature of different cranio-facial organs.

View Article and Find Full Text PDF

The purpose of the research discussed in this article is to explore the possibility of creating hybrid soft ballistic panel (BP) package variants by integrating into their composition layers of graphene-modified para-aramid fabrics in combinations with the different ballistic Kevlar textiles to improve the durability of the first layers of the soft ballistic panel. To address this goal, the liquid-phase exfoliation (LPE) method was used for integrating dispersions into composites to solve a number of topical problems in the stages of the technological sequence development of processing methods and optimizing processing parameters in accordance with the processing specifics of aramid textiles to achieve the desired properties of modified ballistic fabric, including the provision of coating adhesion to the surface to be modified. To test the results, ballistic experiments were performed and the back-face signature (BFS) of bullet impact on a backing material was analysed according to standards.

View Article and Find Full Text PDF

Combined biolistic and cell penetrating peptide delivery for the development of scalable intradermal DNA vaccines.

J Control Release

March 2024

Regenerative Medicine & Cellular Therapies (RMCT), Biodiscovery Institute (BDI), School of Pharmacy, University of Nottingham, Nottingham NG7 2RD, UK; NIHR Nottingham Biomedical Research Centre, University of Nottingham, Nottingham, UK. Electronic address:

Physical-based gene delivery via biolistic methods (such as the Helios gene gun) involve precipitation of nucleic acids onto microparticles and direct transfection through cell membranes of exposed tissue (e.g. skin) by high velocity acceleration.

View Article and Find Full Text PDF

Reliability of ordinal outcomes in forensic black-box studies.

Forensic Sci Int

January 2024

University of California, Office of the Provost and Executive Vice Chancellor, 510 Aldrich Hall, Irvine, CA 92697, USA. Electronic address:

Forensic science disciplines such as latent print examination, bullet and cartridge case comparisons, and shoeprint analysis, involve subjective decisions by forensic experts throughout the examination process. Most of the decisions involve ordinal categories. Examples include a three-category outcome for latent print comparisons (exclusion, inconclusive, identification) and a seven-category outcome for footwear comparisons (exclusion, indications of non-association, inconclusive, limited association of class characteristics, association of class characteristics, high degree of association, identification).

View Article and Find Full Text PDF

The use of finite element models for backface deformation and body armour design: a systematic review.

Comput Methods Biomech Biomed Engin

January 2025

Department of Biomedical Engineering, University of Melbourne, Melbourne, VIC, Australia.

While injuries sustained from body armour backface deformation (BFD) have not been well-documented in military injury trauma registries, data from US law enforcement officers, animal tests and currently available data pertaining to military combatants has shown that BFD can not only cause minor injuries, but also result in serious trauma. However, the nature and severity of injuries sustained depends on a multitude of factors including the projectile type, the impact location and velocity, and the specific type of body armour worn. The difficulties involved in current measurement techniques for ballistic testing has led researchers to seek alternative techniques to evaluate the level of protection from body armour, such as the finite element (FE) method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!