Signal degradation and an array size dictated by the number of available interconnects are the two main limitations inherent to standalone microelectrode arrays (MEAs). A new biochip consisting of an array of microelectrodes with fully-integrated analog and digital circuitry realized in an industrial CMOS process addresses these issues. The device is capable of on-chip signal filtering for improved signal-to-noise ratio (SNR), on-chip analog and digital conversion, and multiplexing, thereby facilitating simultaneous stimulation and recording of electrogenic cell activity. The designed electrode pitch of 250 microm significantly limits the space available for circuitry: a repeated unit of circuitry associated with each electrode comprises a stimulation buffer and a bandpass filter for readout. The bandpass filter has corner frequencies of 100 Hz and 50 kHz, and a gain of 1000. Stimulation voltages are generated from an 8-bit digital signal and converted to an analog signal at a frequency of 120 kHz. Functionality of the read-out circuitry is demonstrated by the measurement of cardiomyocyte activity. The microelectrode is realized in a shifted design for flexibility and biocompatibility. Several microelectrode materials (platinum, platinum black and titanium nitride) have been electrically characterized. An equivalent circuit model, where each parameter represents a macroscopic physical quantity contributing to the interface impedance, has been successfully fitted to experimental results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2004.02.006 | DOI Listing |
Significant advancements in integrated photonics have enabled high-speed and energy efficient systems for various applications, from data communications and high-performance computing to medical diagnosis, sensing, and ranging. However, data storage in these systems has been dominated by electronic memories that in addition to signal conversion between optical and electrical domains, necessitates conversion between analog to digital domains and electrical data movement between processor and memory that reduce the speed and energy efficiency. To date, scalable optical memory with optical control has remained an open problem.
View Article and Find Full Text PDFThis paper breaks away from traditional approaches that merely emulate digital neural networks. Using Mach-Zehnder interferometer (MZI) networks as a case study, we explore the impact of the inherent properties of analog computation on performance and identify the characteristics that optical neural networks (ONNs) components should possess to better adapt to these specific properties. Specifically, we examine the influence of analog computation on bias power and activation functions, as well as the impact of optical pruning on ONN's performance.
View Article and Find Full Text PDFJ Prosthodont
January 2025
The Office of Assistant Dean for Research, School of Dental Medicine, Medical Sciences Campus, University of Puerto Rico, San Juan, Puerto Rico.
Purpose: This study aimed to evaluate and compare the fracture resistance of long-span fixed provisional restorations fabricated using milling, three-dimensional (3D) printing, and conventional methods.
Materials And Methods: Sixty specimens were prepared, divided into four groups of 15 each, corresponding to four fabrication methods: computer-aided design and computer-aided manufacturing (CAD-CAM) milled provisional resins, 3D-printed provisional resins, 3D-printed permanent resins, and conventional bis-acryl restorations reinforced with wire. The specimens underwent a three-point bending test using a universal testing machine to measure fracture resistance, quantified as maximum force (in Newtons).
Sci Rep
January 2025
Space Science Division, Korea Astronomy and Space Science Institute, Daejeon, 34055, Republic of Korea.
This paper reports the proton response function for solution-grown trans-stilbene scintillator from 1 to 25 MeVee and its application for unfolding neutron spectra of Cf-252 and AmBe sources. Low energy proton response was measured by the Time-of-Flight technique at the Korea Research Institute of Standards and Science. In contrast, high energy response was investigated using a 45 MeV proton beam at the Korea Institute of Radiological & Medical Sciences.
View Article and Find Full Text PDFACS Sens
January 2025
Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384, PR China.
The simultaneous detection of electroencephalography (EEG) signals and neurotransmitter levels plays an important role as biomarkers for the assessment and monitoring of emotions and cognition. This paper describes the development of boron and nitrogen codoped graphene-diamond (BNGrD) microelectrodes with a diameter of only 200 μm for sensing EEG signals and dopamine (DA) levels, which have been developed for the first time. The optimized BNGrD microelectrode responded sensitively to both EEG and DA signals, with a signal-to-noise ratio of 9 dB for spontaneous EEG signals and a limit of detection as low as 124 nM for DA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!