Background: Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements.
Methods And Results: In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to -45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to -66.0%).
Conclusions: We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/01.CIR.0000138741.72946.84 | DOI Listing |
Br J Anaesth
January 2025
Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Department of Anaesthesiology and Intensive Care Medicine (CCM/CVK), Berlin, Germany; Medical University of Vienna, Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Clinical Division of General Anaesthesia and Intensive Care Medicine, Vienna, Austria. Electronic address:
Background: Frailty is a predictor of morbidity and mortality in older patients. This study aimed to investigate the influence of frailty status on likelihood, rate, duration, and severity of intraoperative hypotension (IOH), which can lead to severe organ dysfunction.
Methods: Surgical patients (≥70 yr old) with preoperative frailty assessment were analysed retrospectively.
Rev Clin Esp (Barc)
January 2025
Servicio de Medicina Interna, Hospital Universitario General de Valencia; Grupo de trabajo de Insuficiencia Cardíaca yFibrilación Auricular de la SEMI (ICYFA), Spain. Electronic address:
This document provides a comprehensive analysis of the use of point-of-care ultrasound in heart failure (HF), offering detailed recommendations on echocardiography, lung ultrasound, and venous ultrasound. These advanced imaging techniques allow for an accurate, detailed, and non-invasive evaluation of heart failure, facilitating rapid and effective clinical decision-making. Echocardiography enables a rapid assessment of cardiac function at the point of care, enhancing traditional physical examination and being essential for the management of heart failure (HF).
View Article and Find Full Text PDFUltrasonics
January 2025
The Center for Fast Ultrasound Imaging, Department of Health Technology. Technical University of Denmark, Ørsteds Plads Building 349, Lyngby, DK-2800, Denmark.
Non-invasive estimation of pressure differences using 2D synthetic aperture ultrasound imaging offers a precise, low-cost, and risk-free diagnostic tool. Unlike invasive techniques, this preserves natural blood flow and avoids the limitations of devices that occupy lumen space. This paper evaluates a previously published estimator, modified to incorporate Singular Value Decomposition (SVD) echo-cancellation, using data from ten healthy volunteers and one patient.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Ophthalmology, University of Bonn, 53127 Bonn, Germany.
: The PreserFlo™ MicroShunt (PFMS) is a bleb-forming device considered to be less invasive than traditional glaucoma surgery such as trabeculectomy. This study evaluates the 1-year success rates as well as safety profile of PFMS in patients having high intraocular pressure (IOP) and/or glaucoma refractory to drop therapy with a history of prior intravitreal dexamethasone therapy. : A total of 16 eyes after PFMS implantation due to elevated IOP after intravitreal dexamethasone implant (DEX-I) administration were included in this retrospective cohort study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!