Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence.
Materials And Methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P < 0.05 was considered significant.
Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE in identifying the individual nerves. The image quality was also slightly better with DRIVE.
Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejrad.2003.10.019 | DOI Listing |
Eur Radiol
November 2024
Department of Medicine V, Multiple Myeloma Section, University Hospital Heidelberg, Heidelberg, Germany.
Invest Radiol
November 2024
From the Department of Neuroradiology, AP-HP, Henri Mondor University Hospital, Créteil, France (R.A., T.E., I.M., B.B.); University Paris Est Créteil, INSERM, IMRB, Créteil, France (N.O.); Department of Public Health, AP-HP, Henri Mondor University Hospital, Créteil, France (N.O.); EA 4391, Université Paris Est Créteil, Créteil, France (A.C., B.B.); Department of Neurology, AP-HP, Henri Mondor University Hospital, Créteil, France (A.C.); Department of Neuroradiology, A. Rothschild Foundation Hospital, Paris, France (A.L.); Paris Cité University, Paris, France (A.L.); Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland (T.K.); Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland (T.K.); Signal Processing Laboratory (LTS 5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland (T.K.); and Siemens Healthcare SAS, Courbevoie, France (A.M.).
Objectives: Nonenhanced T1-w sequences such as magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) and derived fluid and white matter suppression (FLAWS) have demonstrated high performance for detecting brain parenchymal and cervical spine demyelinating lesions in multiple sclerosis. However, their potential for identifying optic nerve (ON) demyelination remains unexplored. The aim of this study was to evaluate the performance of compressed sensing-accelerated (CS) MP2RAGE-FLAWS imaging for detection of ON demyelination lesions compared with T2-w fat-saturated (FS) TSE imaging in a clinical setting.
View Article and Find Full Text PDFSci Rep
November 2024
Siemens Healthineers Ltd, Seoul, Republic of Korea.
Eur Radiol
October 2024
Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, Technical University of Munich, Munich, Germany.
Objectives: Introducing SPINEPS, a deep learning method for semantic and instance segmentation of 14 spinal structures (ten vertebra substructures, intervertebral discs, spinal cord, spinal canal, and sacrum) in whole-body sagittal T2-weighted turbo spin echo images.
Material And Methods: This local ethics committee-approved study utilized a public dataset (train/test 179/39 subjects, 137 female), a German National Cohort (NAKO) subset (train/test 1412/65 subjects, mean age 53, 694 female), and an in-house dataset (test 10 subjects, mean age 70, 5 female). SPINEPS is a semantic segmentation model, followed by a sliding window approach utilizing a second model to create instance masks from the semantic ones.
J Cardiovasc Magn Reson
December 2024
Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China. Electronic address:
Background: Accurate assessment of the vulnerability of carotid atherosclerotic plaques is crucial for stroke prevention. The three-dimensional (3D) magnetic resonance (MR) vessel wall imaging (VWI) has been increasingly employed to evaluate carotid plaques due to its extensive coverage and isotropic high spatial resolution. However, the accuracy of such techniques lacks validation by histology.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!