Background/aims: Ideal dry weight (DW) can serve as a marker of good quality of life (QOL) in patients receiving chronic hemodialysis. The size of the inferior vena cava (IVC) reflects the intravascular fluid status, and the diameter of IVC correlates indirectly with DW in these patients. Adjusting DW using echocardiographic measurement of the diameter of the IVC thus may be useful in maintenance of a better QOL in patients receiving chronic hemodialysis.
Methods: This study included 119 patients with ages ranging between 27 and 90 years (mean +/- standard deviation of 58.3 +/- 12.8). All of the patients received the IVC diameter (IVCD) measurement by echocardiography every 2 months for 1 year. The study group included 68 patients in whom the DW were adjusted by echocardiographic measurement of the IVCD, while the control group included 51 patients in whom the DW was adjusted by the conventional method. QOL was evaluated using the short form 36 questionnaire (SF-36) at the beginning and at the end of the study. Besides, the Kt/V(urea) value, a parameter of total urea clearance, was measured at the beginning and at the end of the study in patients of both groups.
Results: The scores of physical functioning, physical role functioning, general health and physical component summary showed a prominent improvement in the study group but not in the control group. The impact of periodic echocardiographic evaluation also demonstrated a significant change in the scores of physical functioning, physical role functioning and physical component summary in the study group. Furthermore, the Kt/V(urea) value, a parameter of total urea clearance, also increased significantly in the study group.
Conclusion: Ideal DW is better adjusted by periodic echocardiographic measurement of the IVCD in patients undergoing chronic hemodialysis. Maintenance of a better DW leads to improve hemodialysis quality and QOL in these patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000078636 | DOI Listing |
Pediatr Cardiol
January 2025
Department of Infectious Disease, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, No. 1678 Dongfang Road, Pudong New Area, Shanghai, 200127, China.
Kawasaki disease (KD) is a febrile vasculitis disorder, with coronary artery lesions (CALs) being the most severe complication. Early detection of CALs is challenging due to limitations in echocardiographic equipment (UCG). This study aimed to develop and validate an artificial intelligence algorithm to distinguish CALs in KD patients and support diagnostic decision-making at admission.
View Article and Find Full Text PDFATS Sch
December 2024
Division of Pulmonary, Critical Care, and Sleep Medicine, New York University Langone Health, New York, New York; and.
Background: Advanced critical care echocardiography comprises a specific set of qualitative and quantitative point-of-care echocardiography skills, including a reliable, noninvasive method to measure cardiac output. This technique requires echocardiographic measurement of left ventricular outflow tract (LVOT) diameter and LVOT velocity time integral (VTI). Although there is a demand among critical care fellows to learn these advanced techniques, there are no data describing the acquisition of mastery in these skills.
View Article and Find Full Text PDFCurr Cardiol Rep
January 2025
Department of Cardiovascular Disease, Mayo Clinic, Rochester, MN, USA.
Purpose Of Review: Critical Care Echocardiography (CCE) is now established as an important tool in the intensive care unit (ICU). This paper aims to examine the expanding role of cardiovascular ultrasound in the ICU, focusing on its applications, benefits, and challenges, while highlighting recent advancements shaping the future of critical care echocardiography.
Recent Findings: Non-invasive echocardiographic measurement of hemodynamic parameters including stroke volume, cardiac output, left ventricular filling pressures, and pulmonary pressures have been well-validated against invasive measurements.
Eur J Prev Cardiol
January 2025
Brigham and Women's Hospital, Boston, MA.
Aims: Hepcidin regulates plasma and tissue iron levels. We studied the association of hepcidin levels with the risk of incident heart failure (HF) and cardiac dysfunction in older adults.
Methods: We included adults from the ongoing, longitudinal Atherosclerosis Risk in Communities (ARIC) study who were free from prevalent anemia and HF at Visit 5 (2011-2013) and had available hepcidin and covariate data.
Arch Argent Pediatr
January 2025
Medical Research Unit in Reproductive Medicine, High Specialty Medical Unit, Hospital de Gineco Obstetricia N.° 4, Luis Castelazo Ayala, Instituto Mexicano de Seguro Social, Mexico City, Mexico.
Introduction. Echocardiographic measurement of inferior vena cava diameters and collapsibility index (IVCCI) can estimate right heart chamber function and intravascular volume status. Few reports of reference values for diameters and IVCCI in the pediatric population exist.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!