Object: The authors describe a new type of artificial disc called a single-unit artificial disc (SUAD). It is a single-unit disc without components, and there is no fixation system with which to maintain it in the disc space. It is theorized that its shape, hardness, and surface consistency, together with the compressive force exerted by the body's axial load, should be adequate to maintain the position of the disc in the disc space. In this paper the authors present their results of the kinematic tests in which the stability and integrity of the SUADs was tested.
Methods: Panorobot was used for kinematic test fixture for fatigue testing for different types of SUAD. The test was performed after placing the disc between the C-5 and C-6 vertebral bodies (VBs) obtained from a cadaver. Eight pounds of weight was placed on the top of the container housing the C-5 VB to account for the weight of the head. The robot performed the following movements: 1) flexion-extension, 4.7 degrees each; 2) lateral left-right bending, +/- 2.1 degrees; and 3) coupled rotation, +/- 3.8 degrees. Two flat discs (FDs) of 85 durometer (D), four 30D FD, two recess-edged discs (REDs) of 85D, and four custom-designed discs (CDDs) (custom molded to the disc space) of 30D were tested. None of the discs showed cracks or breakage at the end of the study. After 1 million cycles of excursions all 85D and 30D FD, and both 85D REDs showed weight loss. The 30D CDDs showed minimal weight gain at 1 million cycles. One of the CDDs, tested up to 5 million cycles, did lose weight at 5 million cycles. One 85D FD was extruded after 0.2 million cycles and one 85D RED rotated within the disc space. All other discs maintained their position in the disc space. Dimensional changes were minimal. Scanning electron microscopy of particles collected from one 30D CDD sample after 1 million cycles showed rough irregular granular particles 1 to 600 microm in diameter.
Conclusions: These findings show that a 30D SUAD can maintain its position in the disc space without any anchoring device. Furthermore, at 1 million cycles of testing of 30 D SUAD, FDs did as well as the CDDs. This may be because softer discs mold to changes in dimension of the disc space. In addition the softer discs tend to wear less than the harder ones. Further fatigue study of 10 million cycles is needed to determine long-term efficacy, and the effects of wear on particles surrounding the joints need to be studied.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/spi.2004.1.1.0095 | DOI Listing |
Infect Drug Resist
December 2024
Department of Orthopedics, Affiliated Hospital 6 of Nantong University, The Third People's Hospital of Yancheng, Yancheng, Jiangsu, People's Republic of China.
This report describes a case of lumbar disc infection potentially induced by acupuncture in a 43-year-old male with a history of back pain. After acupuncture treatment at another hospital, the patient experienced worsened pain. Physical examination revealed tenderness at the upper lumbar intervertebral space and paravertebral percussion pain.
View Article and Find Full Text PDFFront Neurol
December 2024
Department of Radiology, Qujing Second People's Hospital, Qujing, China.
Background: CT-routine MRI fusion imaging has recently become available to evaluate spinal anatomy before surgery. Due to the 3-5 mm slice thickness and non-isotropic of routine MRI sequence, the CT-routine MRI fusion imaging is not good. The MRI multiple recalled gradient echo (MERGE) sequence is potentially useful in diagnosis of lumbar degeneration disease due to the better nerve roots visualization, 1 mm slice thickness and its isotropy.
View Article and Find Full Text PDFN Am Spine Soc J
December 2024
Department of Neurosurgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Background: Spine surgical training faces increasing challenges due to restricted working hours and greater sub specialization. Modern simulators offer a promising approach to teaching both simple and complex spinal procedures. This study evaluated the acceptance and efficacy of spine simulator training using a lumbar herniated disc model tested by 16 neurosurgical residents (PGY-1-6), and compared 3D and 2D teaching methods.
View Article and Find Full Text PDFZhongguo Gu Shang
December 2024
Derpartment of Spine Surgery, Nuclear Industry 416 Hospital, Chengdu 610000, Sichuan, China.
Objective: To explore feasibility, clinical and imaging outcomes of percutaneous endoscopic interlaminar discectomy (PEID) for single level large lumbar disc herniation(LDH).
Methods: From October 2018 to March 2023, 31 patients with single level LDH treated with PEID were retrospectively analyzed. Among patients, including 18 males and 13 females, aged from 15 to 40 years old with an average of (28.
Zhongguo Gu Shang
December 2024
The Second Department of Orthopaedics, Hospital of Coast Guard General Corps of Armed Police Forces, Jiaxing 314000, Zhejiang, China.
Objective: To explore characteristics, management strategies and preventive measures of fusion device displacement after oblique lateral interbody fusion (OLIF) in treating lumbar lesions.
Methods: The clinical data of 12 patients with fusion device displacement after OLIF for lumbar lesions in 4 medical centers from October 2014 to December 2018 were retrospectively analyzed, including 4 males and 8 females, aged from 53 to 81 years old;2 patients with lumbar disc degeneration, 4 patients with lumbar spinal stenosis, 3 patients with lumbar degenerative spondylolisthesis and 3 patients with lumbar degenerative kyphosis;preoperative dual-energy X-ray bone mineral density (BMD) was detected in 1 patient with T-value > -1 SD, 5 patients with T-value >-1~-2.5 SD, and 6 patients with T-value <-2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!