Alpha 2-adrenoceptors and 5-HT receptors mediate the antinociceptive effect of new pyrazolines, but not of dipyrone.

Eur J Pharmacol

Laboratório de Psicofarmacologia Neurotoxicidade, Departamento de Fisiologia, Centro de Ciências da Saúde, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil.

Published: August 2004

In this study, we investigated whether spinal noradrenergic and serotonergic systems are involved in the antinociception induced by the novel pyrazolines 3-methyl- and 3-phenyl-5-hydroxy-5-trichloromethyl-4,5-dihydro-1H-1-pyrazole-1-carboxyamide (MPCA and PPCA, respectively), and the pyrazolinone dipyrone in the acetic acid writhing (stretching) test in mice. Intrathecal (i.t.) administration of methysergide (3 and 10 microg) and yohimbine (3 microg), but not of prazosin (0.3 and 1 microg) prevented the antinociceptive action of MPCA and PPCA (500 micromol/kg, s.c.). Dipyrone-induced antinociception (500 micromol/kg, s.c.) was not affected by methysergide or adrenoceptor antagonists. These results suggest that spinal 5-HT receptors and alpha2-adrenoceptors are involved in the antinociception induced by MPCA and PPCA, but not in that elicited by dipyrone.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejphar.2004.05.045DOI Listing

Publication Analysis

Top Keywords

mpca ppca
12
5-ht receptors
8
involved antinociception
8
antinociception induced
8
500 micromol/kg
8
alpha 2-adrenoceptors
4
2-adrenoceptors 5-ht
4
receptors mediate
4
mediate antinociceptive
4
antinociceptive pyrazolines
4

Similar Publications

Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis.

Int Ophthalmol

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).

Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024.

View Article and Find Full Text PDF

Background: To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error.

Methods: A total of 189 eyes of 148 patients undergoing routine cataract surgery were included in the study. Standard and posterior keratometry were measured pre- and postoperatively.

View Article and Find Full Text PDF

Total keratometry versus standard keratometry for intraocular lens power calculation in eyes with keratoconus.

Int Ophthalmol

November 2024

Anterior Segment Surgery Department, Asociación Para Evitar La Ceguera en México I.A.P., Vicente García Torres 46, Barrio San Lucas, CP 04030, Coyoacán, Mexico City, Mexico.

Purpose: To describe the accuracy of monofocal intraocular lens power calculation in patients with keratoconus using total keratometry (TK) and standard keratometry (K) with conventional and keratoconus-modified formulas.

Setting: Asociación Para Evitar la Ceguera en México, Mexico City, Mexico.

Design: Observational, retrospective, non-randomized, comparative study.

View Article and Find Full Text PDF

Purpose: To compare the prediction accuracy of the Barrett toric calculator using standard or integrated keratometry (IK) mode in combination with predicted or measured posterior corneal astigmatism (PCA) in a group of patients with cataract implanted with non-toric IOLs.

Methods: In this retrospective clinical cohort study, the medical records of patients with age-related cataract who underwent phacoemulsification with the implantation of an aspheric monofocal IOL were reviewed. Four methods, including standard keratometry with predicted PCA (PPCA), IK combined with predicted PCA (IK-PPCA), and IK combined with measured PCA derived from IOLMaster 700 (Carl Zeiss Meditec AG) or CASIA2 (Tomey) (IK-MMPCA or IK-CMPCA), were applied to the Barrett toric calculator to calculate the predicted residual astigmatism.

View Article and Find Full Text PDF

Purpose: To assess whether the use of measured posterior corneal astigmatism (PCA) values improves the prediction accuracy of toric intraocular lens power formulas, compared to predicted PCA values, when the orientation of the steep axis of PCA is non-vertical.

Design: Retrospective observational cohort study.

Methods: Four hundred eighteen eyes of 344 patients were included in the study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!