A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Semiautomated high-throughput extraction and cleanup method for the measurement of polybrominated diphenyl ethers and polybrominated and polychlorinated biphenyls in breast milk. | LitMetric

A semiautomated extraction and cleanup method has been developed to measure eight polybrominated diphenyl ethers (PBDEs), 2,2',4,4',5,5'-hexabromobiphenyl (BB-153), and 2,2',4,4',5,5'-hexachlorobiphenyl (CB-153). The method employs solid-phase dispersion on diatomaceous earth in a solid-phase extraction cartridge followed by automated addition of internal standards ((13)C-labeled). Extraction is then performed using an automated modular solid-phase extraction system. The extraction procedure includes drying the sample on diatomaceous earth by pressurized nitrogen and eluting target analytes and lipids with dichloromethane. Lipid content is determined gravimetrically. Lipid determinations performed using this method are compared with other standard methods and with a certified reference material. A relative standard deviation of 7.9% was obtained for 130 determinations of the lipid content in a breast milk quality control sample. Final analytical determination of target analytes was performed by gas chromatography-isotope dilution high-resolution mass spectrometry. Relative standard deviations for the measurements of target analytes for which a labeled internal standard was available were below 10% for analytes at concentrations above 1 ng/g of lipid. Mean recoveries of the (13)C-labeled internal standards ranged from 60 to 89% for the eight PBDE congeners; 74 and 113% were recovered for BB-153 and CB-153, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac0495384DOI Listing

Publication Analysis

Top Keywords

target analytes
12
extraction cleanup
8
cleanup method
8
polybrominated diphenyl
8
diphenyl ethers
8
breast milk
8
diatomaceous earth
8
solid-phase extraction
8
internal standards
8
lipid content
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!